FireCADCalc

Reactor Period and Power Rise after a Reactivity Step

Stable reactor period, prompt jump and power after a step change in reactivity from the one-delayed-group kinetics equations (inhour equation).

Thermal power plant

Inputs

Examples: Illustrative +100 pcm, 60 s+300 pcm, 20 sNegative -500 pcm, 30 s

Accepted: -0.1 to 0.02
Accepted: 0.1 to 1 %
Accepted: 0.01 to 1 1/s
Accepted: 1E-8 to 0.01 s
Accepted: 0 to 100,000 s

Results

One delayed group: ρ = ℓω + βω/(ω + λ). Power n(t)/n₀ = A₁e^(ω₁t) + A₂e^(ω₂t) with n(0) = n₀ and precursors in equilibrium at t = 0.

Stable period (exact one-group)15.242s
Approximate period15.211s
Prompt jump β/(β − ρ)1.8571
Power ratio at time t6.8851
Doubling time T ln 210.565s
Reactivity in dollars0.46154

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative +100 pcm, 60 s. The inputs, in the units selected above:

InputValue
Reactivity step (Δk/k)0.001000 -
Delayed neutron fraction0.65000 %
One-group decay constant of precursors0.076700 1/s
Prompt neutron generation time5.0000e-05 s
Time after the step60.000 s

Applying the formula below gives:

ResultValue
Stable period (exact one-group)71.767 s
Approximate period71.708 s
Prompt jump β/(β − ρ)1.1818
Power ratio at time t2.7260
Doubling time T ln 249.745 s
Reactivity in dollars0.15385

Open this example in the calculator and change any input.

Formula

\(\rho = \ell\omega + \frac{\beta\omega}{\omega + \lambda}, \quad \frac{P(t)}{P_0} = A_1e^{\omega_1 t} + A_2e^{\omega_2 t}, \quad T = \frac{1}{\omega_1}\)

Variables

Symbol Meaning SI unit
\(\rho\) Reactivity step (Δk/k) -
\(\beta\) Delayed neutron fraction -
\(\lambda\) One-group decay constant of precursors 1/s
\(\ell\) Prompt neutron generation time s
\(t\) Time after the step s
\(T\) Stable period (exact one-group) s
\(T \approx (\beta - \rho)/(\lambda\rho)\) Approximate period s
\(P_+/P_0\) Prompt jump β/(β − ρ) -
\(P(t)/P_0\) Power ratio at time t -
\(T_2\) Doubling time T ln 2 s
\(\rho/\beta\) Reactivity in dollars -

Method and standards

One-group point kinetics.

Where it is used

  • Start-up rate and control rod worth checks.
  • Reactor operator training.

Common mistakes

  • Using the six-group β with a one-group λ chosen inconsistently.
  • Applying the approximate period near prompt critical.

Assumptions and limits

  • Point kinetics; no temperature feedback.

References

  • Point reactor kinetics with one effective delayed-neutron group

Questions and answers

Why do delayed neutrons make reactors controllable?

Only 0.65 % of neutrons are delayed, but they lengthen the mean generation time from about 10⁻⁴ s to about 0.08 s, turning a millisecond period into tens of seconds.

What is the prompt jump?

Right after a step, power jumps quickly by β/(β − ρ) as prompt neutrons adjust, then rises on the stable period.

What do the defaults represent?

An illustrative +100 pcm step in a uranium-235 core: β 0.0065, λ 0.0767 /s and a generation time of 50 µs, 60 seconds after the step.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.