PWR Steam Generator: Steam Flow, LMTD and Heat Transfer Area

Steam production, primary flow, log-mean temperature difference to boiling and the heat transfer area of a recirculating PWR steam generator.

Thermal power plant

Inputs

Examples: Illustrative 750 MW SG, 6.9 MPa steamLow steam pressure 5.5 MPa, fouled U 4500Once-through style, 900 MW, 7.6 MPa

Accepted: 0.001 to 5,000 MW
Accepted: 0.1 to 30 MPa
Accepted: 6.85 to 366.85 °C
Accepted: 6.85 to 366.85 °C
Accepted: 0.1 to 20 MPa
Accepted: 6.85 to 326.85 °C
Accepted: 100 to 30,000 W/(m²·K)

Results

Recirculating steam generator: the secondary side is taken at saturation throughout (feedwater mixes with recirculating water in the downcomer), so ΔT_lm = (T_h − T_c)/ln[(T_h − T_sat)/(T_c − T_sat)]. Blowdown and moisture carry-over are neglected. Water and steam properties from IAPWS-IF97.

Steam saturation temperature269.97°C
Steam flow (dry saturated)1,452.5t/h
Primary flow14,243t/h
Log-mean temperature difference36.050K
Required UA20,804kW/K
Heat transfer area4,623.2m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 750 MW SG, 6.9 MPa steam. The inputs, in the units selected above:

InputValue
Steam generator duty750.00 MW
Primary pressure15.500 MPa
Primary inlet (hot-leg) temperature325.00 °C
Primary outlet (cold-leg) temperature292.00 °C
Steam pressure6.9000 MPa
Feedwater temperature227.00 °C
Overall heat transfer coefficient6,000.0 W/(m²·K)

Applying the formula below gives:

ResultValue
Steam saturation temperature284.86 °C
Steam flow (dry saturated)1,502.7 t/h
Primary flow14,243 t/h
Log-mean temperature difference19.115 K
Required UA39,237 kW/K
Heat transfer area6,539.5 m²

Open this example in the calculator and change any input.

Formula

\(\dot m_s = \frac{Q}{h_g(p_s) - h_{fw}}, \quad \Delta T_{lm} = \frac{T_h - T_c}{\ln\frac{T_h - T_{sat}}{T_c - T_{sat}}}, \quad A = \frac{Q}{U\Delta T_{lm}}\)

Variables

Symbol Meaning SI unit
\(Q\) Steam generator duty W
\(p_p\) Primary pressure Pa
\(T_h\) Primary inlet (hot-leg) temperature K
\(T_c\) Primary outlet (cold-leg) temperature K
\(p_s\) Steam pressure Pa
\(T_{fw}\) Feedwater temperature K
\(U\) Overall heat transfer coefficient W/(m²·K)
\(T_{sat}\) Steam saturation temperature K
\(\dot m_s\) Steam flow (dry saturated) kg/s
\(\dot m_p\) Primary flow kg/s
\(\Delta T_{lm}\) Log-mean temperature difference K
\(UA\) Required UA W/K
\(A\) Heat transfer area m²

Method and standards

Steam generator heat balance.

Where it is used

  • PWR performance monitoring and fouling trending.
  • Teaching and preliminary sizing.

Common mistakes

  • Using an LMTD with the feedwater temperature as the cold-side inlet.
  • Forgetting tube plugging when comparing area.

Assumptions and limits

  • Saturated secondary throughout; dry steam.

References

  • Heat balance and LMTD of a recirculating steam generator

Questions and answers

Why is the steam pressure only about 7 MPa?

The secondary must boil below the primary cold-leg temperature (about 290 °C), which limits the saturation pressure; this caps PWR cycle efficiency near 33–35 %.

What U do steam generators achieve?

About 5,000–7,000 W/(m²·K) clean, with thin Inconel tubes and boiling on the outside.

What do the defaults represent?

An illustrative 750 MW steam generator: primary 325 → 292 °C at 15.5 MPa, steam at 6.9 MPa, feedwater 227 °C, U = 6,000 W/(m²·K).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.