Worked example
Example: Illustrative 1 MeV, 0.1 mGy. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Neutron energy | 1.0000 MeV |
| Neutron absorbed dose | 0.10000 mGy |
Applying the formula below gives:
| Result | Value |
|---|---|
| Radiation weighting factor | 20.692 |
| Equivalent dose | 2.0692 mSv |
Open this example in the calculator and change any input.
Formula
\(w_R = 2.5 + 18.2e^{-[\ln E_n]^2/6}\;(E_n < 1\text{ MeV}), \quad 5.0 + 17.0e^{-[\ln(2E_n)]^2/6}\;(1\text{–}50\text{ MeV})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_n\) | Neutron energy | J |
| \(D\) | Neutron absorbed dose | Gy |
| \(w_R\) | Radiation weighting factor | - |
| \(H\) | Equivalent dose | Gy |
Method and standards
Radiation weighting.
Where it is used
- Neutron dosimetry and shielding assessments.
- Radiation protection training.
Common mistakes
- Using older step-function quality factors with ICRP 103 limits.
- Applying w_R to effective dose without tissue factors.
Assumptions and limits
- Single neutron energy; external exposure.
References
- ICRP radiation weighting factor for neutrons
Questions and answers
Why do neutrons have a high weighting factor?
Their recoil protons deposit energy densely, causing more biological damage per gray than gamma rays; the factor peaks at about 20.7 near 1 MeV.
What about thermal neutrons?
About 2.5: slow neutrons cause damage mostly through capture gammas and low-energy protons.
What do the defaults represent?
An illustrative 1 MeV neutron field giving 0.1 mGy absorbed dose.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
ICRP Publication 103, The 2007 Recommendations of the International Commission on Radiological Protection (2007)