Worked example
Example: Illustrative 1200 then 455 cpm after 5 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First gross count rate | 1,200.0 1/min |
| Second gross count rate | 455.00 1/min |
| Background count rate | 20.000 1/min |
| Time between the measurements | 5.0000 h |
| Counting time of each measurement | 10.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Decay constant | 0.19958 1/h |
| Half-life | 3.4729 h |
| Mean life | 5.0104 h |
| Relative standard uncertainty of the half-life | 1.8441 % |
Open this example in the calculator and change any input.
Formula
\(\lambda = \frac{1}{\Delta t}\ln\frac{C_1 - B}{C_2 - B}, \quad T_{1/2} = \frac{\ln 2}{\lambda}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_1\) | First gross count rate | 1/s |
| \(C_2\) | Second gross count rate | 1/s |
| \(B\) | Background count rate | 1/s |
| \(\Delta t\) | Time between the measurements | s |
| \(t_c\) | Counting time of each measurement | s |
| \(\lambda\) | Decay constant | 1/s |
| \(T_{1/2}\) | Half-life | s |
| \(\tau\) | Mean life | s |
| \(u_{T_{1/2}}/T_{1/2}\) | Relative standard uncertainty of the half-life | - |
Method and standards
Half-life measurement.
Where it is used
- Identifying an unknown radionuclide.
- Teaching laboratory radioactivity.
Common mistakes
- Forgetting background.
- Using rates in different time units.
Assumptions and limits
- Single nuclide; no dead-time correction.
References
- Exponential decay fitted to two net count rates with Poisson statistics
Questions and answers
Why subtract background?
The detector counts natural radiation all the time; leaving it in makes the source appear to decay more slowly.
How can the result be made more precise?
Count longer, wait longer between measurements (at least one half-life) and use a stronger source relative to background.
What do the defaults represent?
An illustrative source counting 1,200 then 455 counts per minute five hours later, background 20 per minute, 10-minute counts.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 2