FireCADCalc

Fuel Rod Fission Gas Release and Plenum Pressure

Fission gas produced and released in a fuel rod over its life and the resulting rod internal pressure from the helium fill, free volume and gas temperature.

Thermal power plant

Inputs

Examples: Illustrative PWR rod 18 kW/m, 1500 d, 5 % releaseHigh release 20 %, 2000 dBWR rod 15 kW/m, 1 MPa fill, 25 cm3

Accepted: 1 to 60 kW/m
Accepted: 0.1 to 5 m
Accepted: 1 to 11,574 d
Accepted: 0.1 to 0.4
Accepted: 0 to 100 %
Accepted: 0.1 to 1,000 cm³
Accepted: 0.1 to 5 MPa
Accepted: 26.85 to 1,226.8 °C

Results

Ideal gas in a fixed free volume: fissions = q'Lt/200 MeV; released gas = y f N_f/N_A. Free volume shrinks with pellet swelling and clad creep-down, which raises the pressure further; design limits keep rod pressure below the coolant pressure.

Fissions in the rod3.9474e+23
Fission gas released (mol)0.032774
Helium fill (mol)0.009847
Helium pressure hot4.4346MPa
Rod internal pressure19.195MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PWR rod 18 kW/m, 1500 d, 5 % release. The inputs, in the units selected above:

InputValue
Average linear heat rate18.000 kW/m
Fuel stack length3.6600 m
Time at power1,500.0 d
Stable xenon plus krypton atoms per fission0.25000 -
Fraction of the gas released to the free volume5.0000 %
Plenum and gap free volume12.000 cm³
Helium fill pressure at 20 °C2.0000 MPa
Gas temperature in operation326.85 °C

Applying the formula below gives:

ResultValue
Fissions in the rod2.6645e+23
Fission gas released (mol)0.005531
Helium fill (mol)0.009847
Helium pressure hot4.0935 MPa
Rod internal pressure6.3927 MPa

Open this example in the calculator and change any input.

Formula

\(N_f = \frac{\bar q'Lt}{E_f}, \quad n_{fg} = \frac{yfN_f}{N_A}, \quad p = \frac{(n_{He} + n_{fg})RT_g}{V}\)

Variables

Symbol Meaning SI unit
\(\bar q'\) Average linear heat rate W/m
\(L\) Fuel stack length m
\(t\) Time at power s
\(y\) Stable xenon plus krypton atoms per fission -
\(f\) Fraction of the gas released to the free volume -
\(V\) Plenum and gap free volume m³
\(p_0\) Helium fill pressure at 20 °C Pa
\(T_g\) Gas temperature in operation K
\(N_f\) Fissions in the rod -
\(n_{fg}\) Fission gas released (mol) -
\(n_{He}\) Helium fill (mol) -
\(p_{He}\) Helium pressure hot Pa
\(p\) Rod internal pressure Pa

Method and standards

Rod gas inventory.

Where it is used

  • Fuel design and end-of-life rod pressure checks.
  • Teaching fuel behaviour.

Common mistakes

  • Using total fission gas instead of the released fraction.
  • Forgetting to heat the fill gas to operating temperature.

Assumptions and limits

  • Ideal gas; constant free volume and power.

References

  • Ideal-gas balance of fission gas release

Questions and answers

Why is fission gas a problem?

Xenon and krypton released from the pellets raise rod pressure and lower the gap conductance, which heats the fuel and releases more gas.

How much gas is released?

A few per cent of the gas made at moderate temperatures, rising steeply above about 1,200–1,400 °C in the pellet centre.

What do the defaults represent?

An illustrative PWR rod at 18 kW/m for 1,500 days, 0.25 gas atoms per fission, 5 % release, 12 cm³ free volume, 2 MPa helium fill and gas at 327 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 8, Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.