Decay Heat after Reactor Shutdown (Way-Wigner)

Fission-product decay heat as a fraction of operating power after shutdown, the decay power and the energy released between two times, by the Way-Wigner formula.

Thermal power plant

Inputs

Examples: Illustrative 3000 MWt, 1 year, 1 h to 1 day10 s to 10 min after 2 yearsSpent fuel 30 to 100 days after 3 years, 1000 MWt

Accepted: 1E-6 to 10,000 MW
Accepted: 1.157E-5 to 115,740 d
Accepted: 0.00027778 to 277,780 h
Accepted: 0.00027778 to 277,780 h

Results

Way–Wigner: P/P₀ = 0.0622[t^−0.2 − (t + T₀)^−0.2], times in seconds. Accuracy about ±50 % below 10 s and above 100 days; within roughly 10–20 % in between. Licensing calculations use the ANS-5.1 decay-heat standard instead.

Decay heat fraction at t1.0125%
Decay heat power at t30.376MW
Decay heat fraction at t₂0.44379%
Decay energy released between t and t₂1,423.2GJ
Average decay power between t and t₂17.188MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3000 MWt, 1 year, 1 h to 1 day. The inputs, in the units selected above:

InputValue
Operating thermal power before shutdown3,000.0 MW
Operating time at that power365.25 d
Time after shutdown1.0000 h
Later time (for energy released from t to t₂)24.000 h

Applying the formula below gives:

ResultValue
Decay heat fraction at t1.0125 %
Decay heat power at t30.376 MW
Decay heat fraction at t₂0.44379 %
Decay energy released between t and t₂1,423.2 GJ
Average decay power between t and t₂17.188 MW

Open this example in the calculator and change any input.

Formula

\(\frac{P}{P_0} = 0.0622\left[t^{-0.2} - (t + T_0)^{-0.2}\right], \quad E = 0.0622P_0\left[\frac{t^{0.8} - (t + T_0)^{0.8}}{0.8}\right]_{t}^{t_2}\)

Variables

Symbol Meaning SI unit
\(P_0\) Operating thermal power before shutdown W
\(T_0\) Operating time at that power s
\(t\) Time after shutdown s
\(t_2\) Later time (for energy released from t to t₂) s
\(P/P_0\) Decay heat fraction at t -
\(P(t)\) Decay heat power at t W
\(P(t_2)/P_0\) Decay heat fraction at t₂ -
\(E\) Decay energy released between t and t₂ J
\(\bar P\) Average decay power between t and t₂ W

Method and standards

Way–Wigner decay-heat estimate.

Where it is used

  • Shutdown cooling, spent fuel pool and cask heat estimates.
  • Emergency cooling and station blackout studies (screening).

Common mistakes

  • Using it for licensing (use the ANS-5.1 standard).
  • Entering times in hours where the formula needs seconds (the calculator converts).

Assumptions and limits

  • Fission products only; actinide decay heat (U-239, Np-239) is not included.

References

  • Way–Wigner approximation for fission-product decay heat

Questions and answers

How large is decay heat?

About 6–7 % of full power just after shutdown, about 1 % after an hour and 0.4–0.5 % after a day: still megawatts for a large reactor.

Why does it matter so much?

Cooling must continue after shutdown; loss of it melted the cores at Three Mile Island and Fukushima.

What do the defaults represent?

An illustrative 3,000 MW thermal reactor after a year at power, one hour after shutdown, with the energy released up to one day.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 8, El-Wakil, Powerplant Technology (McGraw-Hill, 1984), ch. 9-11

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.