FireCADCalc

Control Rod Integral and Differential Worth (Sine-Squared Law)

Integral and differential reactivity worth of a control rod at a given withdrawal in a bare core with a cosine axial flux, from its total worth.

Thermal power plant

Inputs

Examples: Illustrative 1500 pcm, 3.66 m core, 1.2 m outMid-height 1.83 mResearch core 0.6 m, 3000 pcm, 0.15 m

Accepted: 1 to 100,000
Accepted: 0.1 to 10 m
Accepted: 0 to 10 m

Results

First-order perturbation in a cosine flux: worth ∝ ∫φ² over the withdrawn length, giving ρ(z)/ρ_T = z/H − sin(2πz/H)/(2π) and the largest differential worth at mid-height. Real rods show shadowing and flux tilts; use measured S-curves for operation.

Worth withdrawn so far (pcm)750.00
Worth still inserted (pcm)750.00
Differential worth (pcm per cm)8.1967
Fraction of total worth withdrawn50.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1500 pcm, 3.66 m core, 1.2 m out. The inputs, in the units selected above:

InputValue
Total rod worth (pcm)1,500.0 -
Core height3.6600 m
Rod withdrawal from the bottom (fully inserted = 0)1.2000 m

Applying the formula below gives:

ResultValue
Worth withdrawn so far (pcm)281.08
Worth still inserted (pcm)1,218.9
Differential worth (pcm per cm)6.0245
Fraction of total worth withdrawn18.739 %

Open this example in the calculator and change any input.

Formula

\(\frac{\rho(z)}{\rho_T} = \frac{z}{H} - \frac{1}{2\pi}\sin\frac{2\pi z}{H}, \quad \frac{d\rho}{dz} = \frac{\rho_T}{H}\left(1 - \cos\frac{2\pi z}{H}\right)\)

Variables

Symbol Meaning SI unit
\(\rho_T\) Total rod worth (pcm) -
\(H\) Core height m
\(z\) Rod withdrawal from the bottom (fully inserted = 0) m
\(\rho(z)\) Worth withdrawn so far (pcm) -
\(\rho_T - \rho(z)\) Worth still inserted (pcm) -
\(d\rho/dz\) Differential worth (pcm per cm) -
\(\rho(z)/\rho_T\) Fraction of total worth withdrawn -

Method and standards

Rod worth curve.

Where it is used

  • Start-up and rod calibration planning.
  • Reactor operator training.

Common mistakes

  • Assuming worth is linear with withdrawal.
  • Ignoring interaction between rod banks.

Assumptions and limits

  • Bare core, cosine axial flux, small perturbation.

References

  • Control rod worth by perturbation theory in a cosine flux

Questions and answers

Why is a rod most effective at mid-height?

Worth goes with the square of the local flux, which peaks in the middle of the core.

Why is it called an S-curve?

Integral worth against withdrawal rises slowly at the ends and steeply in the middle, tracing an S.

What do the defaults represent?

An illustrative 1,500 pcm rod in a 3.66 m core, withdrawn 1.2 m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.