FireCADCalc

Coolant, Clad and Fuel Temperatures with a Chopped Cosine Flux

Coolant outlet temperature and the height and value of the maximum clad surface and fuel centreline temperatures for a chopped-cosine axial power shape.

Thermal power plant

Inputs

Examples: Illustrative PWR subchannel, 30 kW/m peakHot channel 42 kW/m, low flow 0.25 kg/sShort core 2 m, extrapolated 2.2 m, no fuel drop

Accepted: 0.1 to 100 kW/m
Accepted: 0.1 to 10 m
Accepted: 0.1 to 20 m
Accepted: 0.36 to 360,000 kg/h
Accepted: 1 to 20 kJ/(kg·K)
Accepted: 0 to 1,026.8 °C
Accepted: 1 to 30 mm
Accepted: 100 to 200,000 W/(m²·K)
Accepted: 0 to 3,000 K

Results

q'(z) = q'₀cos(πz/L_e), z from −L/2 to +L/2. Coolant T_m(z) = T_in + q'₀L_e/(πṁc_p)[sin(πz/L_e) + sin(πL/2L_e)]; each temperature T_m + q'(z)R peaks where tan(πz/L_e) = L_e/(πṁc_pR). Single-phase coolant with constant c_p and h; the fuel resistance comes from the peak ΔT entered.

Coolant outlet temperature311.51°C
Height of the maximum clad temperature above mid-height0.36279m
Maximum clad surface temperature327.89°C
Height of the maximum centreline temperature above mid-height0.36279m
Maximum fuel centreline temperature327.89°C
Channel power34.658kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PWR subchannel, 30 kW/m peak. The inputs, in the units selected above:

InputValue
Peak linear heat rate (at mid-height)30.000 kW/m
Heated length3.6600 m
Extrapolated length of the cosine (≥ L)3.9000 m
Coolant flow in the channel1,080.0 kg/h
Coolant specific heat5.8000 kJ/(kg·K)
Coolant inlet temperature292.00 °C
Rod outer diameter9.5000 mm
Coolant heat transfer coefficient35,000 W/(m²·K)
Centreline-to-clad-surface temperature difference at the peak1,200.0 K

Applying the formula below gives:

ResultValue
Coolant outlet temperature334.61 °C
Height of the maximum clad temperature above mid-height0.79507 m
Maximum clad surface temperature349.12 °C
Height of the maximum centreline temperature above mid-height0.021622 m
Maximum fuel centreline temperature1,542.2 °C
Channel power74.137 kW

Open this example in the calculator and change any input.

Formula

\(T_m(z) = T_{in} + \frac{q'_0L_e}{\pi\dot mc_p}\left[\sin\frac{\pi z}{L_e} + \sin\frac{\pi L}{2L_e}\right], \quad \tan\frac{\pi z_{max}}{L_e} = \frac{L_e}{\pi\dot mc_pR}\)

Variables

Symbol Meaning SI unit
\(q'_0\) Peak linear heat rate (at mid-height) W/m
\(L\) Heated length m
\(L_e\) Extrapolated length of the cosine (≥ L) m
\(\dot m\) Coolant flow in the channel kg/s
\(c_p\) Coolant specific heat J/(kg·K)
\(T_{in}\) Coolant inlet temperature K
\(D\) Rod outer diameter m
\(h\) Coolant heat transfer coefficient W/(m²·K)
\(\Delta T_{f,0}\) Centreline-to-clad-surface temperature difference at the peak K
\(T_{out}\) Coolant outlet temperature K
\(z_c\) Height of the maximum clad temperature above mid-height m
\(T_{co,max}\) Maximum clad surface temperature K
\(z_f\) Height of the maximum centreline temperature above mid-height m
\(T_{cl,max}\) Maximum fuel centreline temperature K
\(P_{ch}\) Channel power W

Method and standards

Chopped-cosine channel analysis.

Where it is used

  • Hot channel analysis in core design.
  • Teaching reactor thermal hydraulics.

Common mistakes

  • Placing the clad maximum at mid-height.
  • Using the core-average flow for the hot channel.

Assumptions and limits

  • Single phase; constant properties; no cross-flow between channels.

References

  • Axial temperature distribution in a heated channel with a chopped-cosine heat flux

Questions and answers

Why is the maximum clad temperature above mid-height?

The coolant keeps heating up along the channel, so the hottest clad sits downstream of the peak heat flux, where the falling flux and rising coolant temperature balance.

Why is the centreline maximum nearer mid-height?

The fuel temperature drop is large and follows the heat flux, so the coolant rise matters less.

What do the defaults represent?

An illustrative PWR subchannel: 30 kW/m peak, 3.66 m heated length, 3.9 m extrapolated, 0.30 kg/s, c_p 5,800 J/(kg·K), inlet 292 °C and a 1,200 K fuel drop at the peak.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.