Worked example
Example: Illustrative BWR bundle 5 MW, 16 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Channel pressure | 7.0000 MPa |
| Inlet temperature (subcooled) | 278.00 °C |
| Channel (bundle) power | 5.0000 MW |
| Channel flow | 57,600 kg/h |
| Channel flow area | 98.000 cm² |
| Distribution parameter | 1.1300 - |
| Drift velocity | 0.24000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet enthalpy | 1,225.8 kJ/kg |
| Exit enthalpy | 1,538.3 kJ/kg |
| Exit equilibrium quality | 17.999 % |
| Fraction of length to the start of bulk boiling (uniform heating) | 13.310 % |
| Exit void fraction, homogeneous | 81.636 % |
| Exit void fraction, drift flux | 70.720 % |
| Exit mixture density (drift flux) | 242.42 kg/m³ |
| Mass flux | 1,632.7 kg/(m²·s) |
Open this example in the calculator and change any input.
Formula
\(x_e = \frac{h_{in} + Q/\dot m - h_f}{h_{fg}}, \quad \alpha = \frac{x}{C_0\left[x + (1 - x)\rho_g/\rho_f\right] + \rho_gV_{gj}/G}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Channel pressure | Pa |
| \(T_{in}\) | Inlet temperature (subcooled) | K |
| \(Q\) | Channel (bundle) power | W |
| \(\dot m\) | Channel flow | kg/s |
| \(A\) | Channel flow area | m² |
| \(C_0\) | Distribution parameter | - |
| \(V_{gj}\) | Drift velocity | m/s |
| \(h_{in}\) | Inlet enthalpy | J/kg |
| \(h_{out}\) | Exit enthalpy | J/kg |
| \(x_e\) | Exit equilibrium quality | - |
| \(z_b/L\) | Fraction of length to the start of bulk boiling (uniform heating) | - |
| \(\alpha_h\) | Exit void fraction, homogeneous | - |
| \(\alpha\) | Exit void fraction, drift flux | - |
| \(\rho_m\) | Exit mixture density (drift flux) | kg/m³ |
| \(G\) | Mass flux | kg/(m²·s) |
Method and standards
Channel heat balance with drift-flux void fraction.
Where it is used
- BWR core thermal hydraulics.
- Boiling channels in boilers and evaporators.
Common mistakes
- Using equilibrium quality where subcooled boiling is significant.
- Using the homogeneous model for void reactivity.
Assumptions and limits
- Steady state; uniform heating for the boiling height.
References
- Channel energy balance and the Zuber–Findlay drift-flux model
Questions and answers
Why is the drift-flux void lower than homogeneous?
Steam moves faster than the liquid (slip), and gathers in the faster centre of the channel (C₀ > 1), so less volume is occupied by steam than a no-slip model predicts.
Why do voids matter in a BWR?
Steam voids reduce moderation; the void coefficient is negative, so more voids lower the power, and recirculation flow is used to control power.
What do the defaults represent?
An illustrative BWR bundle: 7.0 MPa, inlet 278 °C, 5 MW, 16 kg/s, 98 cm² flow area, C₀ 1.13 and V_gj 0.24 m/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Zuber and Findlay, Average volumetric concentration in two-phase flow systems, J. Heat Transfer 87 (1965) 453–468, Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 11