FireCADCalc

Wet Scrubber: Adiabatic Saturation Temperature and Water Evaporated

Outlet temperature and humidity of flue gas leaving a wet scrubber (adiabatic saturation) and the water it evaporates, with IF97 water properties.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Stack and chimneyDust collector (ESP, bag filter, cyclone)

Inputs

Examples: 180 °C gas, Y 0.10Drier gas 150 °C

Results

Water vapour enthalpy from IAPWS-IF97 at low partial pressure (ideal-gas behaviour). The saturated plume condenses: reheat or line the stack.

Gas out (saturated)61.076°C
Humidity out0.15924kg/kg
Water evaporated5.9241t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 180 °C gas, Y 0.10. The inputs, in the units selected above:

InputValue
Dry flue gas flow100.00 t/h
Gas in180.00 °C
Humidity in (kg water per kg dry gas)0.10000 kg/kg
Dry gas specific heat1.0500 kJ/(kg·K)
Dry gas molar mass30.000 kg/kmol
Gas pressure (absolute)100.00 kPa
Make-up water temperature30.000 °C

Applying the formula below gives:

ResultValue
Gas out (saturated)61.076 °C
Humidity out0.15924 kg/kg
Water evaporated5.9241 t/h

Open this example in the calculator and change any input.

Formula

\(c_{p,g}T_1 + Y_1 h_v(T_1) + (Y_s - Y_1)h_l(T_w) = c_{p,g}T_s + Y_s h_v(T_s), \quad Y_s = \frac{M_w}{M_g}\frac{p_s(T_s)}{p - p_s(T_s)}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Dry flue gas flow kg/s
\(T_1\) Gas in K
\(Y_1\) Humidity in (kg water per kg dry gas) kg/kg
\(c_{p,g}\) Dry gas specific heat J/(kg·K)
\(M_g\) Dry gas molar mass kg/kmol
\(p\) Gas pressure (absolute) Pa
\(T_w\) Make-up water temperature K
\(T_s\) Gas out (saturated) K
\(Y_s\) Humidity out kg/kg
\(\dot m_v\) Water evaporated kg/s

Method and standards

Adiabatic saturation energy balance per kg of dry gas, solved by bisection for the saturation temperature. Saturation pressure from IAPWS-IF97; the vapour enthalpy h_v is the IF97 value at 700 Pa (low partial pressure, ideal-gas behaviour) and the make-up water enthalpy h_l the IF97 liquid value at 101.325 kPa.

Where it is used

  • Wet scrubber and quench design.
  • Stack reheat studies.

Common mistakes

  • Wet gas flow used as dry.

Assumptions and limits

  • Adiabatic; ideal-gas vapour.
  • One dry-gas specific heat from the inlet temperature down to saturation; the true mean over a wide range (up to 500 °C) differs by a few per cent.
  • The saturation temperature is searched between 0.35 °C and the lower of the gas inlet temperature and the boiling point at the gas pressure; inputs with no solution in that range are rejected.

References

  • Adiabatic saturation energy balance; saturation pressure and vapour enthalpy from IAPWS-IF97

Questions and answers

Why does the gas cool so much?

Evaporating water takes its latent heat from the gas until the gas is saturated.

Typical outlet?

Around 50–65 °C for boiler flue gas, depending on its moisture.

Water use?

The evaporated water is lost with the gas; add blowdown and droplet carry-over for make-up.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.