FireCADCalc

Flue Gas Cooling by Dilution Air

Ambient air to mix with hot flue gas to reach a target temperature, and the extra gas mass flow the fan and filter must then handle.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolFan and blowerDust collector (ESP, bag filter, cyclone)

Inputs

Examples: 250 to 150 °CEmergency 300 to 200 °C

Results

Dilution raises the gas flow and the fan power; compare with spray cooling.

Dilution air40.484t/h
Air per kg of gas0.67474kg/kg
Total gas after mixing100.48t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 to 150 °C. The inputs, in the units selected above:

InputValue
Flue gas flow100.00 t/h
Gas specific heat1.1000 kJ/(kg·K)
Gas temperature250.00 °C
Target mixed temperature150.00 °C
Ambient air temperature30.000 °C
Air specific heat1.0060 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Dilution air91.120 t/h
Air per kg of gas0.91120 kg/kg
Total gas after mixing191.12 t/h

Open this example in the calculator and change any input.

Formula

\(\dot m_a = \frac{\dot m_g c_{p,g}(T_g - T_m)}{c_{p,a}(T_m - T_a)}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Flue gas flow kg/s
\(c_{p,g}\) Gas specific heat J/(kg·K)
\(T_g\) Gas temperature K
\(T_m\) Target mixed temperature K
\(T_a\) Ambient air temperature K
\(c_{p,a}\) Air specific heat J/(kg·K)
\(\dot m_a\) Dilution air kg/s
\(\dot m_a/\dot m_g\) Air per kg of gas kg/kg
\(\dot m_t\) Total gas after mixing kg/s

Method and standards

Energy balance between the gas cooling from \(T_g\) to \(T_m\) and the air warming from \(T_a\) to \(T_m\). The output is the mass flow; convert it to volume at the fan temperature with the gas density there.

Where it is used

  • Filter protection design.
  • Fan capacity checks.

Common mistakes

  • Mixing temperatures in a ratio of volumes.

Assumptions and limits

  • Constant specific heats: use the mean gas value between \(T_m\) and \(T_g\) and the mean air value between \(T_a\) and \(T_m\). From very hot gas (above about 1000 °C) the mean gas specific heat is noticeably higher than at the stack.
  • A warning appears above 3 kg of air per kg of gas.

References

  • Energy balance ṁ_a c_p
  • a (T_m − T_a) = ṁ_g c_p
  • g (T_g − T_m)

Questions and answers

When is dilution air used?

As emergency protection for filters or when water spray is not possible.

Cost?

More gas through the ID fan and filter; the fan may run out of capacity.

O₂ reading?

Dilution raises the O₂ downstream: correct emissions to reference O₂.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.