Worked example
Example: 500 m3 fermenter. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fermenter working volume | 500.00 m³ |
| Inoculum share of fermenter volume | 10.000 % |
| Laboratory culture volume | 10.000 L |
| Step-up ratio per stage | 10.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Seed volume | 50.000 m³ |
| Propagation stages | 4.0000 |
Open this example in the calculator and change any input.
Formula
\(V_s = V_f i, \quad N = \left\lceil \frac{\ln(V_s/V_0)}{\ln r} \right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Fermenter working volume | m³ |
| \(i\) | Inoculum share of fermenter volume | - |
| \(V_0\) | Laboratory culture volume | m³ |
| \(r\) | Step-up ratio per stage | - |
| \(V_s\) | Seed volume | m³ |
| \(N\) | Propagation stages | - |
Method and standards
Scale-up.
Where it is used
- Propagation plant design.
Common mistakes
- Total volume instead of working volume.
Assumptions and limits
- Fixed step-up ratio.
References
- Geometric scale-up: stages = ⌈log(V_s/V_0)/log r⌉
Questions and answers
Why a step-up ratio?
Each vessel is seeded at about a tenth of its volume so yeast dominates bacteria.
Inoculum share?
About 10 % of the fermenter in batch plants.
Dry yeast?
Active dry yeast can skip the laboratory stages.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.