Mash Cooling Duty and Cooling Water

Heat to remove when cooling liquefied mash to fermentation temperature, and the cooling water flow for a water temperature rise, by a sensible heat balance.

Distillery and ethanol

Inputs

Examples: 60 t/h from 85 to 32 °CMolasses wash 40 t/h

Results

Recover the first part of this heat into incoming slurry or process water before using cooling-tower water.

Cooling duty1,151.1kW
Cooling water164.96t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 t/h from 85 to 32 °C. The inputs, in the units selected above:

InputValue
Mash flow60.000 t/h
Mash specific heat3.8000 kJ/(kg·K)
Mash in (after liquefaction)85.000 °C
Mash out (to fermenters)32.000 °C
Cooling water temperature rise8.0000 K

Applying the formula below gives:

ResultValue
Cooling duty3,356.7 kW
Cooling water360.78 t/h

Open this example in the calculator and change any input.

Formula

\(Q = \dot m c_p (T_1 - T_2), \quad \dot m_w = \frac{Q}{c_w\Delta T_w}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Mash flow kg/s
\(c_p\) Mash specific heat J/(kg·K)
\(T_1\) Mash in (after liquefaction) K
\(T_2\) Mash out (to fermenters) K
\(\Delta T_w\) Cooling water temperature rise K
\(Q\) Cooling duty W
\(\dot m_w\) Cooling water kg/s
\(c_w\) Specific heat of water 4 186.8 J/(kg·K)

Method and standards

Sensible heat balance; water c_w = 4.1868 kJ/(kg·K).

Where it is used

  • Mash cooler sizing.
  • Cooling-tower load estimates.

Common mistakes

  • Using water's specific heat for the mash.

Assumptions and limits

  • No phase change.

References

  • Sensible heat balance Q = ṁ c_p ΔT (definition)
  • Jacques
  • Lyons and Kelsall (eds.)
  • The Alcohol Textbook
  • 4th ed. (2003)
  • ch. 2: liquefaction at 80–90 °C
  • fermentation set near 32 °C

Questions and answers

What specific heat should I use?

Grain mash at 30 % solids is about 3.6–3.9 kJ/(kg·K).

Why recover heat?

Mash leaves liquefaction at 80–90 °C; half of the duty can preheat slurry water.

What water rise is usual?

6–10 K with cooling-tower water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.