Worked example
Example: 250 t/d grain, 30 % solids. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Grain | 250.00 t/d |
| Grain moisture | 13.000 % |
| Target slurry dry solids | 30.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water (and backset) to add | 475.00 t/d |
| Mash (slurry) | 725.00 t/d |
| Water-to-grain ratio | 1.9000 |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{\dot m_g (1 - w)}{TS}, \quad \dot m_w = \dot m_s - \dot m_g\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Grain | kg/s |
| \(w\) | Grain moisture | - |
| \(TS\) | Target slurry dry solids | - |
| \(\dot m_w\) | Water (and backset) to add | kg/s |
| \(\dot m_s\) | Mash (slurry) | kg/s |
| \(r\) | Water-to-grain ratio | - |
Method and standards
Dry-solids balance.
Where it is used
- Grain distillery design.
- Mash control.
Common mistakes
- Wet grain counted as dry.
Assumptions and limits
- Steady flow.
- Backset (thin stillage) is counted as water, but it carries several per cent of dissolved solids, so the real slurry solids are somewhat above TS when backset is used. Count those solids in the target if you need the true figure.
References
- Dry-solids balance
Questions and answers
Why about 30 % solids?
Higher solids raise wash strength but thicken the mash.
Backset?
Part of the water can be thin stillage; it counts in the water here.
Grain moisture?
Use as-received moisture so the balance closes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.