FireCADCalc

Fermenter Volume and Number for a KLPD Plant

Wash volume per day, total fermenter volume and number of fermenters for a plant capacity, wash strength, fermentation cycle and working fill.

Distillery and ethanolTank and drum

Inputs

Examples: 100 KLPD batchGrain 200 KLPD

Results

Add a fermenter for cleaning and maintenance standby.

Wash per day1,561.9m³/d
Total gross fermenter volume4,593.8m³
Fermenters4.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 KLPD batch. The inputs, in the units selected above:

InputValue
Plant capacity (absolute alcohol)100.00 kL/d
Wash strength9.0000 %
Distillation efficiency98.500 %
Cycle time (fill, ferment, empty, clean)36.000 h
Working fill of the fermenter85.000 %
One fermenter, gross600.00 m³

Applying the formula below gives:

ResultValue
Wash per day1,128.0 m³/d
Total gross fermenter volume1,990.6 m³
Fermenters4.0000

Open this example in the calculator and change any input.

Formula

\(\dot V_w = \frac{\dot V_e}{\eta_d s_v}, \quad V_g = \frac{\dot V_w t_c}{\phi}, \quad N = \lceil V_g / V_u \rceil\)

Variables

Symbol Meaning SI unit
\(\dot V_e\) Plant capacity (absolute alcohol) m³/s
\(s_v\) Wash strength -
\(\eta_d\) Distillation efficiency -
\(t_c\) Cycle time (fill, ferment, empty, clean) s
\(\phi\) Working fill of the fermenter -
\(V_u\) One fermenter, gross m³
\(\dot V_w\) Wash per day m³/s
\(V_g\) Total gross fermenter volume m³
\(N\) Fermenters -

Method and standards

Volume balance.

Where it is used

  • Plant design and expansion.
  • Bottleneck checks.

Common mistakes

  • Cycle time without cleaning.

Assumptions and limits

  • Steady output.

References

  • Volume balance: wash = AA/(η_d s); volume = wash × cycle time / fill

Questions and answers

Continuous fermentation?

Use the residence time instead of the batch cycle.

Why does wash strength matter so much?

Wash volume and fermenter count vary inversely with it.

Working fill?

Foam and CO₂ need headspace; 80–90 % is usual.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.