Worked example
Example: 71 g/L in 30 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ethanol in final wash | 71.000 g/L |
| Ethanol at start (from seed) | 3.0000 g/L |
| Fermentation time | 30.000 h |
| Working volume | 500.00 m³ |
| Ethanol density at 20 °C | 789.24 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volumetric productivity | 2.2667 g/(L·h) |
| Ethanol output while fermenting (fill, empty and cleaning excluded) | 1,133.3 kg/h |
| Ethanol output while fermenting (absolute) | 34.464 kL/d |
Open this example in the calculator and change any input.
Formula
\(P = \frac{c_e - c_0}{t}, \quad \dot m_e = P V\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(c_e\) | Ethanol in final wash | kg/m³ |
| \(c_0\) | Ethanol at start (from seed) | kg/m³ |
| \(t\) | Fermentation time | s |
| \(V\) | Working volume | m³ |
| \(\rho_e\) | Ethanol density at 20 °C | kg/m³ |
| \(P\) | Volumetric productivity | kg/(m³·s) |
| \(\dot m_e\) | Ethanol output of the fermenter | kg/s |
| \(\dot V_e\) | Ethanol output (absolute) | m³/s |
Method and standards
Definition.
Where it is used
- Fermentation comparison and trials.
Common mistakes
- Cycle time used for fermentation time.
Assumptions and limits
- Batch average over the fermentation time only. The outputs are rates while fermenting; over a full cycle with filling, emptying and cleaning the plant output is lower.
References
- Definition P = (c_e − c_0)/t
Questions and answers
Typical productivity?
About 1.5–3 g/L·h for batch molasses fermentations; continuous and cell-recycle systems more.
Why does it matter?
Fermenter volume needed is inversely proportional to it.
Cycle time?
Productivity uses fermentation time only; plant output also counts filling and cleaning.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.