Worked example
Example: Meredith: 36 000 BTU/gal, 82 %, 1.1 kWh, 5 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ethanol made (undenatured) | 12,500 L/h |
| Fuel (natural gas) per denatured gallon, BTU | 36,000 - |
| Boiler efficiency | 82.000 % |
| Electricity per denatured gallon, kWh | 1.1000 - |
| Denaturant added per volume of ethanol | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel per kg of undenatured ethanol | 13.349 MJ/kg |
| Fuel per litre of undenatured ethanol | 2.9265 kWh/L |
| Steam heat per litre | 2.3997 kWh/L |
| Electricity per litre | 0.30512 kWh/L |
| Fuel input | 36.582 MW |
| Electric load | 3,814.0 kW |
Open this example in the calculator and change any input.
Formula
\(q_L = q_g\,\frac{1 + \delta}{3.785\ \mathrm{L}}, \quad s_L = \eta_b q_L, \quad w_L = w\,\frac{1 + \delta}{3.785\ \mathrm{L}}, \quad q_u = \frac{q_L}{\rho_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_E\) | Ethanol made (undenatured) | m³/s |
| \(q_g\) | Fuel (natural gas) per denatured gallon, BTU | - |
| \(\eta_b\) | Boiler efficiency | - |
| \(w\) | Electricity per denatured gallon, kWh | - |
| \(\delta\) | Denaturant added per volume of ethanol | - |
| \(q_u\) | Fuel per kg of undenatured ethanol | J/kg |
| \(q_L\) | Fuel per litre of undenatured ethanol | J/m³ |
| \(s_L\) | Steam heat per litre | J/m³ |
| \(w_L\) | Electricity per litre | J/m³ |
| \(\dot Q_g\) | Fuel input | W |
| \(P\) | Electric load | W |
| \(\rho_e\) | Ethanol density at 20 °C, 789.24 kg/m³ (OIML R 22) | kg/m³ |
Method and standards
Meredith's accounting converted to SI.
Where it is used
- Benchmarking plants.
- Carbon intensity estimates.
Common mistakes
- Mixing per denatured and undenatured gallons.
- Using HHV and LHV figures together.
Assumptions and limits
- US gallon basis of the source; BTU and kWh per gallon are entered as plain numbers and converted inside with the exact NIST factors.
- The gas BTU are on whatever heating value basis the source figure uses (gross or net); the boiler efficiency must be on the same basis.
References
- Jacques
- Lyons and Kelsall (eds.)
- The Alcohol Textbook
- 4th ed. (Nottingham University Press, 2003)
- ch. 25 (Meredith)
- energy use and energy users in contemporary ethanol plants
- US gallon 3.785 411 784 L and IT BTU 1 055.055 852 62 J (NIST SP 811)
Questions and answers
Why convert to undenatured ethanol?
US plants report per gallon of denatured fuel (5 % gasoline); the ethanol made is 100/105 of that volume.
Steam or gas BTU?
Gas BTU is fuel into the boiler; steam BTU is after boiler losses.
Where does the steam go?
Cooking, distillation and the dryhouse; Meredith shows that extra mash water is heated three times.