FireCADCalc

Fuel Ethanol Plant Energy per Litre (Meredith)

Thermal and electrical energy of a fuel ethanol plant per litre of undenatured ethanol from figures per denatured gallon (Meredith, Alcohol Textbook ch. 25).

Distillery and ethanolBoiler

Inputs

Examples: Meredith: 36 000 BTU/gal, 82 %, 1.1 kWh, 5 %Efficient plant

Alcohol Textbook: about 36 000 BTU of gas per gallon in modern plants.
0.7–1.2 kWh per gallon; 1.1 as a conservative average.

Results

Meredith's example: 36 000 BTU/gal of gas × 105/100 = 37 800 BTU per undenatured gallon; at 82 % boiler efficiency about 31 000 steam BTU; electricity 1.155 kWh per undenatured gallon. Fuel per kg uses 789.24 kg/m³.

Fuel per kg of undenatured ethanol10.859MJ/kg
Fuel per litre of undenatured ethanol2.3807kWh/L
Steam heat per litre2.0236kWh/L
Electricity per litre0.21662kWh/L
Fuel input49.598MW
Electric load4,512.9kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Meredith: 36 000 BTU/gal, 82 %, 1.1 kWh, 5 %. The inputs, in the units selected above:

InputValue
Ethanol made (undenatured)12,500 L/h
Fuel (natural gas) per denatured gallon, BTU36,000 -
Boiler efficiency82.000 %
Electricity per denatured gallon, kWh1.1000 -
Denaturant added per volume of ethanol5.0000 %

Applying the formula below gives:

ResultValue
Fuel per kg of undenatured ethanol13.349 MJ/kg
Fuel per litre of undenatured ethanol2.9265 kWh/L
Steam heat per litre2.3997 kWh/L
Electricity per litre0.30512 kWh/L
Fuel input36.582 MW
Electric load3,814.0 kW

Open this example in the calculator and change any input.

Formula

\(q_L = q_g\,\frac{1 + \delta}{3.785\ \mathrm{L}}, \quad s_L = \eta_b q_L, \quad w_L = w\,\frac{1 + \delta}{3.785\ \mathrm{L}}, \quad q_u = \frac{q_L}{\rho_e}\)

Variables

Symbol Meaning SI unit
\(\dot V_E\) Ethanol made (undenatured) m³/s
\(q_g\) Fuel (natural gas) per denatured gallon, BTU -
\(\eta_b\) Boiler efficiency -
\(w\) Electricity per denatured gallon, kWh -
\(\delta\) Denaturant added per volume of ethanol -
\(q_u\) Fuel per kg of undenatured ethanol J/kg
\(q_L\) Fuel per litre of undenatured ethanol J/m³
\(s_L\) Steam heat per litre J/m³
\(w_L\) Electricity per litre J/m³
\(\dot Q_g\) Fuel input W
\(P\) Electric load W
\(\rho_e\) Ethanol density at 20 °C, 789.24 kg/m³ (OIML R 22) kg/m³

Method and standards

Meredith's accounting converted to SI.

Where it is used

  • Benchmarking plants.
  • Carbon intensity estimates.

Common mistakes

  • Mixing per denatured and undenatured gallons.
  • Using HHV and LHV figures together.

Assumptions and limits

  • US gallon basis of the source; BTU and kWh per gallon are entered as plain numbers and converted inside with the exact NIST factors.
  • The gas BTU are on whatever heating value basis the source figure uses (gross or net); the boiler efficiency must be on the same basis.

References

  • Jacques
  • Lyons and Kelsall (eds.)
  • The Alcohol Textbook
  • 4th ed. (Nottingham University Press, 2003)
  • ch. 25 (Meredith)
  • energy use and energy users in contemporary ethanol plants
  • US gallon 3.785 411 784 L and IT BTU 1 055.055 852 62 J (NIST SP 811)

Questions and answers

Why convert to undenatured ethanol?

US plants report per gallon of denatured fuel (5 % gasoline); the ethanol made is 100/105 of that volume.

Steam or gas BTU?

Gas BTU is fuel into the boiler; steam BTU is after boiler losses.

Where does the steam go?

Cooking, distillation and the dryhouse; Meredith shows that extra mash water is heated three times.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.