Worked example
Example: Five 1 000 m3 fermenters at 100 m3/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mash feed | 100.00 m³/h |
| Working volume of each fermenter | 1,000.0 m³ |
| Fermenters in the train | 5.0000 - |
| Ethanol leaving the last fermenter | 110.00 g/L |
| Maximum specific growth rate of the yeast | 0.30000 1/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dilution rate F/V | 0.10000 1/h |
| Residence time per fermenter | 10.000 h |
| Total residence time | 50.000 h |
| Time to steady state of one fermenter (three residence times) | 30.000 h |
| Volumetric productivity of the train | 2.2000 g/(L·h) |
| Washout margin (must exceed 1) | 3.0000 |
Open this example in the calculator and change any input.
Formula
\(D = \frac{F}{V}, \quad T = \frac1D, \quad Q_P = \frac{P F}{nV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F\) | Mash feed | m³/s |
| \(V\) | Working volume of each fermenter | m³ |
| \(n\) | Fermenters in the train | - |
| \(P\) | Ethanol leaving the last fermenter | kg/m³ |
| \(\mu_{max}\) | Maximum specific growth rate of the yeast | 1/s |
| \(D\) | Dilution rate F/V | 1/s |
| \(T\) | Residence time per fermenter | s |
| \(nT\) | Total residence time | s |
| \(3T\) | Time to steady state of one fermenter (three residence times) | s |
| \(Q_P\) | Volumetric productivity of the train | kg/(m³·s) |
| \(\mu_{max}/D\) | Washout margin (must exceed 1) | - |
Method and standards
Chemostat definitions as given in the Alcohol Textbook.
Where it is used
- Designing fermenter trains.
- Changing feed rates safely.
Common mistakes
- Using total instead of working volume.
- Expecting steady state right after a change.
Assumptions and limits
- Equal volumes; no side feeds after fermenter 1.
- The time to steady state is for a single fermenter; in a train the later vessels settle later, so the last one takes longer than 3T.
References
- Jacques
- Lyons and Kelsall (eds.)
- The Alcohol Textbook
- 4th ed. (Nottingham University Press, 2003)
- ch. 11 (Ingledew)
- single-stage and multistage continuous culture
Questions and answers
What is the dilution rate?
Feed flow divided by working volume: the fraction of the fermenter replaced each hour.
Why must D stay below μmax?
In a single-stage fermenter without recycle, yeast that grows slower than it is diluted is washed out.
Why a train?
Several fermenters in series approach batch conversion while keeping continuous flow.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.