FireCADCalc

Continuous Fermentation: Dilution Rate and Train

Dilution rate, residence time, time to steady state and productivity of a continuous fermenter train, with a yeast washout check (Alcohol Textbook ch. 11).

Distillery and ethanolTank and drum

Inputs

Examples: Five 1 000 m3 fermenters at 100 m3/hFast single stage (washout)

The Alcohol Textbook: fuel alcohol plants run trains of four or five fermenters.

Results

Steady state needs about three residence times (some studies use six) after any change of feed. That is for one fermenter: later vessels of the train settle later, so allow longer for the last one.

The dilution rate exceeds the maximum growth rate: yeast washes out of the first fermenter unless it is recycled.

Dilution rate F/V0.333331/h
Residence time per fermenter3.0000h
Total residence time3.0000h
Time to steady state of one fermenter (three residence times)9.0000h
Volumetric productivity of the train26.667g/(L·h)
Washout margin (must exceed 1)0.90000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Five 1 000 m3 fermenters at 100 m3/h. The inputs, in the units selected above:

InputValue
Mash feed100.00 m³/h
Working volume of each fermenter1,000.0 m³
Fermenters in the train5.0000 -
Ethanol leaving the last fermenter110.00 g/L
Maximum specific growth rate of the yeast0.30000 1/h

Applying the formula below gives:

ResultValue
Dilution rate F/V0.10000 1/h
Residence time per fermenter10.000 h
Total residence time50.000 h
Time to steady state of one fermenter (three residence times)30.000 h
Volumetric productivity of the train2.2000 g/(L·h)
Washout margin (must exceed 1)3.0000

Open this example in the calculator and change any input.

Formula

\(D = \frac{F}{V}, \quad T = \frac1D, \quad Q_P = \frac{P F}{nV}\)

Variables

Symbol Meaning SI unit
\(F\) Mash feed m³/s
\(V\) Working volume of each fermenter m³
\(n\) Fermenters in the train -
\(P\) Ethanol leaving the last fermenter kg/m³
\(\mu_{max}\) Maximum specific growth rate of the yeast 1/s
\(D\) Dilution rate F/V 1/s
\(T\) Residence time per fermenter s
\(nT\) Total residence time s
\(3T\) Time to steady state of one fermenter (three residence times) s
\(Q_P\) Volumetric productivity of the train kg/(m³·s)
\(\mu_{max}/D\) Washout margin (must exceed 1) -

Method and standards

Chemostat definitions as given in the Alcohol Textbook.

Where it is used

  • Designing fermenter trains.
  • Changing feed rates safely.

Common mistakes

  • Using total instead of working volume.
  • Expecting steady state right after a change.

Assumptions and limits

  • Equal volumes; no side feeds after fermenter 1.
  • The time to steady state is for a single fermenter; in a train the later vessels settle later, so the last one takes longer than 3T.

References

  • Jacques
  • Lyons and Kelsall (eds.)
  • The Alcohol Textbook
  • 4th ed. (Nottingham University Press, 2003)
  • ch. 11 (Ingledew)
  • single-stage and multistage continuous culture

Questions and answers

What is the dilution rate?

Feed flow divided by working volume: the fraction of the fermenter replaced each hour.

Why must D stay below μmax?

In a single-stage fermenter without recycle, yeast that grows slower than it is diluted is washed out.

Why a train?

Several fermenters in series approach batch conversion while keeping continuous flow.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.