Worked example
Example: 1,780 rpm motor, pump at 1,200 rpm, 600 N.m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Motor speed | 1,780.0 rpm |
| Load speed | 1,200.0 rpm |
| Load torque at this speed | 600.00 N·m |
| Load power at full speed (for the peak loss) | 150.00 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Input power | 111.84 kW |
| Load power | 75.398 kW |
| Slip loss | 36.442 kW |
| Coupling efficiency | 67.416 % |
| Slip | 32.584 % |
| Peak slip loss on a cubic load (at 2/3 speed) | 22.222 kW |
Open this example in the calculator and change any input.
Formula
\(P_{slip} = T(n_m - n_l), \quad \eta = \frac{n_l}{n_m}, \quad P_{slip,max} = \frac{4}{27}P_r\ \ (\text{cubic load})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n_m\) | Motor speed | rad/s |
| \(n_l\) | Load speed | rad/s |
| \(T\) | Load torque at this speed | N·m |
| \(P_r\) | Load power at full speed (for the peak loss) | W |
| \(P_{in}\) | Input power | W |
| \(P_{out}\) | Load power | W |
| \(P_{slip}\) | Slip loss | W |
| \(\eta\) | Coupling efficiency | - |
| \(s\) | Slip | - |
| \(P_{slip,max}\) | Peak slip loss on a cubic load (at 2/3 speed) | W |
Method and standards
Slip power of torque-transmitting couplings.
Where it is used
- Comparing slip couplings with VFDs.
- Sizing coupling cooling.
Common mistakes
- Assuming slip couplings save energy like a VFD at low speed.
- Using rated torque at reduced speed.
Assumptions and limits
- Windage and friction neglected.
Questions and answers
Why is efficiency the speed ratio?
Input power is T × motor speed and output T × load speed; with equal torque their ratio is n_l/n_m.
Where is the worst loss?
For a centrifugal load with torque ∝ speed², the slip power (n_m − n_l)·k n_l² peaks at n_l = 2n_m/3, where it is 4/27 of full-load power.
What do the defaults represent?
A 1,780 rpm motor driving a pump at 1,200 rpm with 600 N·m: 111.8 kW in, 75.4 kW out, 36.4 kW of slip heat and 67 % efficiency; a 150 kW friction-only system peaks at 22 kW of slip loss.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 9.2.1, permanent magnet adjustable speed drives and eddy-current couplings (slip power equations, Fig. 7)