Worked example
Example: Illustrative 260 mm pump trimmed for 85 m3/h at 40 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Full impeller diameter | 260.00 mm |
| Shut-off head of the full impeller | 62.000 m |
| Flow at a known point on the full-diameter curve | 100.00 m³/h |
| Head at that point | 50.000 m |
| Duty flow wanted | 85.000 m³/h |
| Duty head wanted | 40.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Trimmed impeller diameter | 230.36 mm |
| Trim ratio | 88.600 % |
| Full-diameter point on the same system parabola | 95.937 m³/h |
| Head at that point | 50.955 m |
| Power at the trimmed duty as a share of the full-impeller power on the same parabola | 69.551 % |
Open this example in the calculator and change any input.
Formula
\(H = H_0 - aQ^2, \quad a = \frac{H_0 - H_1}{Q_1^2}, \quad Q^* = \sqrt{\frac{H_0}{a + H_d/Q_d^2}}, \quad \frac{D_2}{D_1} = \frac{Q_d}{Q^*}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_1\) | Full impeller diameter | m |
| \(H_0\) | Shut-off head of the full impeller | m |
| \(Q_1\) | Flow at a known point on the full-diameter curve | m³/s |
| \(H_1\) | Head at that point | m |
| \(Q_d\) | Duty flow wanted | m³/s |
| \(H_d\) | Duty head wanted | m |
| \(D_2\) | Trimmed impeller diameter | m |
| \(D_2/D_1\) | Trim ratio | - |
| \(Q^*\) | Full-diameter point on the same system parabola | m³/s |
| \(H^*\) | Head at that point | m |
| \((D_2/D_1)^3\) | Power at the trimmed duty as a share of the full-impeller power on the same parabola | - |
Method and standards
Impeller trim.
Where it is used
- Matching an oversized pump to its real duty instead of throttling.
- Energy audits of pumping systems.
Common mistakes
- Scaling the diameter with the duty flow alone (Q_d/Q₁), ignoring the parabola.
- Trimming below the maker's minimum diameter.
Assumptions and limits
- Parabolic pump curve; affinity laws; efficiency held.
References
- Affinity laws for impeller diameter along the system parabola
Questions and answers
How do I calculate the trimmed impeller diameter?
Find where the parabola H = (H_d/Q_d²)Q² meets the full-diameter curve; the trim ratio is Q_d divided by the flow at that point.
How much can an impeller be trimmed?
Typically down to the smallest diameter on the maker's curve, often about 80 % of the full size.
What do the defaults represent?
A pump with a 260 mm impeller giving 50 m at 100 m³/h (62 m shut-off) to be trimmed for 85 m³/h at 40 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008)