Worked example
Example: Illustrative single volute at half flow. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pump head at the operating flow | 55.000 m |
| Impeller outside diameter | 320.00 mm |
| Impeller width at the outlet, including the shrouds | 35.000 mm |
| Flow as a share of the best-efficiency flow | 50.000 % |
| Thrust factor at shut-off | 0.36000 - |
| Liquid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Radial thrust factor at this flow | 0.27000 |
| Radial thrust | 1.6278 kN |
Open this example in the calculator and change any input.
Formula
\(F_r = K \rho g H D_2 B_2, \quad K = K_0\left[1 - \left(\frac{Q}{Q_{BEP}}\right)^2\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Pump head at the operating flow | m |
| \(D_2\) | Impeller outside diameter | m |
| \(B_2\) | Impeller width at the outlet, including the shrouds | m |
| \(Q/Q_{BEP}\) | Flow as a share of the best-efficiency flow | - |
| \(K_0\) | Thrust factor at shut-off | - |
| \(\rho\) | Liquid density | kg/m³ |
| \(K\) | Radial thrust factor at this flow | - |
| \(F_r\) | Radial thrust | N |
Method and standards
Radial thrust.
Where it is used
- Bearing and shaft checks for pumps run at part load.
- Explaining seal and wear-ring failures at low flow.
Common mistakes
- Using the impeller passage width instead of the width over the shrouds.
- Applying the single-volute factor to a diffuser pump.
Assumptions and limits
- Stepanoff's empirical factor; steady force only.
References
- Stepanoff radial thrust factor for volute casings
Questions and answers
Why is radial thrust worst at shut-off?
The pressure round a single volute is uniform only at the design flow; at zero flow the imbalance is largest.
How does a double volute help?
Its two tongues 180° apart balance most of the force, reducing K to about a tenth.
What do the defaults represent?
An illustrative single-volute pump, 320 mm impeller 35 mm wide over the shrouds, at half its best-efficiency flow and 55 m head.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Stepanoff, Centrifugal and Axial Flow Pumps, 2nd ed. (Wiley, 1957), Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008)