Worked example
Example: Illustrative 0.5 m3/s, 600 mm bell. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 1,800.0 m³/h |
| Bell or inlet diameter | 600.00 mm |
| Froude coefficient | 2.3000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet velocity | 1.7684 m/s |
| Froude number | 0.72902 |
| Minimum submergence | 1.6061 m |
| Submergence in diameters | 2.6768 |
Open this example in the calculator and change any input.
Formula
\(S = D(1 + c\,Fr_D), \quad Fr_D = \frac{V}{\sqrt{gD}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Flow | m³/s |
| \(D\) | Bell or inlet diameter | m |
| \(c\) | Froude coefficient | - |
| \(V\) | Inlet velocity | m/s |
| \(Fr_D\) | Froude number | - |
| \(S\) | Minimum submergence | m |
| \(S/D\) | Submergence in diameters | - |
Method and standards
Submergence rule.
Where it is used
- Pump sump and wet well design.
- Cooling water and river intakes.
Common mistakes
- Using the pipe instead of the bell diameter.
- Ignoring poor approach flow.
Assumptions and limits
- Vertical suction; reasonably uniform approach flow.
References
- Froude-number submergence rule for intakes
Questions and answers
What happens with too little submergence?
Surface vortices draw air into the pump, causing noise, vibration, loss of head and damage.
Does a bigger bell help?
Yes: a larger bell lowers inlet velocity and Froude number, cutting the submergence needed.
What do the defaults represent?
An illustrative 0.5 m³/s pump with a 600 mm suction bell and c = 2.3.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008)