Worked example
Example: Illustrative 250 mm impeller at 2950 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 100.00 m³/h |
| Pump head | 55.000 m |
| Speed | 2,950.0 rpm |
| Impeller outside diameter | 250.00 mm |
| Wear ring (seal) diameter | 130.00 mm |
| Hub (shaft sleeve) diameter | 50.000 mm |
| Static pressure rise of the impeller as a share of the head | 75.000 % |
| Liquid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Side-space pressure at the wear ring above suction | 2.6799 bar |
| Pressure force on the back shroud | 2.7886 kN |
| Inlet momentum force | 0.068088 kN |
| Net axial thrust towards the suction | 2.7205 kN |
Open this example in the calculator and change any input.
Formula
\(p(r) = p_s + R_p \rho g H - \frac{\rho\omega^2}{8}\left(r_2^2 - r^2\right), \quad F_a = \int_{r_h}^{r_w} \left[p(r) - p_s\right] 2\pi r\,dr - \frac{\rho Q^2}{\pi(r_w^2 - r_h^2)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Flow | m³/s |
| \(H\) | Pump head | m |
| \(n\) | Speed | rad/s |
| \(D_2\) | Impeller outside diameter | m |
| \(D_w\) | Wear ring (seal) diameter | m |
| \(D_h\) | Hub (shaft sleeve) diameter | m |
| \(R_p\) | Static pressure rise of the impeller as a share of the head | - |
| \(\rho\) | Liquid density | kg/m³ |
| \(p_w - p_s\) | Side-space pressure at the wear ring above suction | Pa |
| \(F_p\) | Pressure force on the back shroud | N |
| \(F_m\) | Inlet momentum force | N |
| \(F_a\) | Net axial thrust towards the suction | N |
Method and standards
Axial thrust.
Where it is used
- Thrust bearing selection for end-suction pumps.
- Judging the effect of worn wear rings and balance holes.
Common mistakes
- Ignoring the rotation of the side-space fluid (overestimates the thrust).
- Forgetting that worn wear rings change the force.
Assumptions and limits
- Rotation factor 0.5; no leakage flow effect; static pressure rise as a share of head.
References
- Side-space pressure with fluid rotating at half impeller speed (rotation factor 0.5)
Questions and answers
Which way does the axial thrust act?
Towards the suction on a single-suction closed impeller without balancing.
Why assume the side-space liquid turns at half speed?
It is dragged by the rotating shroud and held back by the stationary casing; about half speed is the usual estimate for smooth, narrow gaps.
What do the defaults represent?
An illustrative 250 mm impeller at 2950 rpm, 100 m³/h and 55 m, wear ring 130 mm, sleeve 50 mm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gülich, Centrifugal Pumps, 3rd ed. (Springer, 2014), Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008)