Worked example
Example: 300 mm, 7 blades at 20 deg, 1,480 rpm, volute. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Impeller outlet diameter | 0.30000 m |
| Inlet (eye) to outlet radius ratio | 0.40000 - |
| Outlet width | 0.020000 m |
| Speed | 1,480.0 rpm |
| Flow through the impeller | 180.00 m³/h |
| Outlet blade angle (from tangential) | 20.000 ° |
| Number of blades | 7.0000 - |
| Pfleiderer collector factor | Volute, 0.8 |
| Hydraulic efficiency | 85.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tip speed | 23.248 m/s |
| Meridional (radial) velocity | 2.6526 m/s |
| Whirl without slip | 15.960 m/s |
| Wiesner slip, V_s/U_2 | 0.14978 |
| Pfleiderer slip coefficient | 0.36518 |
| Euler head without slip | 37.835 m |
| Euler head with Wiesner slip | 29.580 m |
| Euler head with Pfleiderer slip | 27.714 m |
| Pump head (Wiesner × hydraulic efficiency) | 25.143 m |
Open this example in the calculator and change any input.
Formula
\(U_2 = \frac{\omega D_2}{2}, \quad V_{m2} = \frac{Q}{\pi D_2b_2}, \quad V_{\theta2,\infty} = U_2 - \frac{V_{m2}}{\tan\beta_{b2}}\)
\(\frac{V_s}{U_2} = \frac{\sqrt{\sin\beta_{b2}}}{n_b^{0.7}}, \quad p = \frac{a(1 + \sin\beta_{b2})\,r_2^2}{n_b\,(r_2^2 - r_1^2)/2}, \quad H = \frac{U_2V_{\theta2}}{g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_2\) | Impeller outlet diameter | m |
| \(r_1/r_2\) | Inlet (eye) to outlet radius ratio | - |
| \(b_2\) | Outlet width | m |
| \(n\) | Speed | rad/s |
| \(Q\) | Flow through the impeller | m³/s |
| \(\beta_{b2}\) | Outlet blade angle (from tangential) | rad |
| \(n_b\) | Number of blades | - |
| \(a\) | Pfleiderer collector factor | - |
| \(\eta_h\) | Hydraulic efficiency | - |
| \(U_2\) | Tip speed | m/s |
| \(V_{m2}\) | Meridional (radial) velocity | m/s |
| \(V_{\theta2,\infty}\) | Whirl without slip | m/s |
| \(\sigma_W\) | Wiesner slip, V_s/U_2 | - |
| \(p\) | Pfleiderer slip coefficient | - |
| \(H_\infty\) | Euler head without slip | m |
| \(H_{th,W}\) | Euler head with Wiesner slip | m |
| \(H_{th,P}\) | Euler head with Pfleiderer slip | m |
| \(H\) | Pump head (Wiesner × hydraulic efficiency) | m |
Method and standards
Euler turbomachine equation with Wiesner and Pfleiderer slip.
Where it is used
- Preliminary impeller design.
- Estimating the effect of trimming or blade count.
Common mistakes
- Measuring the blade angle from the radial direction.
- Treating the Euler head as the delivered head.
Assumptions and limits
- Radial impeller, no inlet swirl, outlet blockage ignored.
Questions and answers
Why does slip reduce the head?
With a finite number of blades the flow leaves the impeller at a flatter angle than the blades, so the outlet whirl and therefore the Euler head are lower.
What do the defaults represent?
A 300 mm, seven-blade impeller with 20° blades and a 20 mm outlet at 1,480 rpm passing 0.05 m³/s into a volute: tip speed 23.2 m/s, Wiesner slip 0.150, Euler head 37.8 m without slip and 29.6 m with it.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 2.1.1, eqs. 15 and 52 and Table 2