FireCADCalc

Flat Rolling: Draft, Reduction, Contact Length and Roll Force

Draft, reduction, roll contact length and approximate roll force for flat rolling from entry and exit thickness, roll radius, width and mean flow stress.

Inputs

Examples: 25 to 20 mm hot stripCold strip 3 to 2.5 mm

Average of the flow stress over the strain of the pass, at the rolling temperature.

Results

Frictionless estimate; friction raises the force (roughly 20 % more for typical passes).

Draft5.0000mm
Reduction20.000%
Contact length √(RΔh)35.355mm
Roll force σ̄ w L1,909.2kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 to 20 mm hot strip. The inputs, in the units selected above:

InputValue
Entry thickness25.000 mm
Exit thickness20.000 mm
Roll radius250.00 mm
Strip width300.00 mm
Mean flow stress in the pass180.00 MPa

Applying the formula below gives:

ResultValue
Draft5.0000 mm
Reduction20.000 %
Contact length √(RΔh)35.355 mm
Roll force σ̄ w L1,909.2 kN

Open this example in the calculator and change any input.

Formula

\(\Delta h = h_0 - h_f, \quad L = \sqrt{R\Delta h}, \quad F = \bar\sigma w L\)

Variables

Symbol Meaning SI unit
\(h_0\) Entry thickness m
\(h_f\) Exit thickness m
\(R\) Roll radius m
\(w\) Strip width m
\(\bar\sigma\) Mean flow stress in the pass Pa
\(\Delta h\) Draft m
\(r\) Reduction -
\(L\) Contact length √(RΔh) m
\(F\) Roll force σ̄ w L N

Method and standards

Slab estimate.

Where it is used

  • Rolling mill checks.
  • Examinations.

Common mistakes

  • Diameter for radius.
  • Room-temperature flow stress for hot rolling.

Assumptions and limits

  • Plane strain, no friction.
  • The largest draft the rolls can bite, about μ²R, is not checked (no friction input), and roll flattening, which lengthens the contact under high force, is ignored.

References

  • Flat rolling: L = √(RΔh)
  • F ≈ σ̄ w L (Kalpakjian; Groover)

Questions and answers

25 to 20 mm, 250 mm rolls, 300 mm wide, 180 MPa?

Contact 35.4 mm: about 1909 kN.

Why smaller rolls for thin strip?

Contact length and force fall with roll radius.

Hot rolling?

Use the flow stress at the rolling temperature and strain rate.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.