FireCADCalc

Injection Moulding Clamping Force

Clamping force for an injection moulding tool from the projected area of the parts and runner, cavity pressure, number of cavities and a safety margin.

Inputs

Examples: Four 120 cm2 partsSingle large cover

From the material maker or flow analysis; depends on flow length and wall thickness.

Results

Total projected area830.00cm²
Clamping force2,739.0kN
Clamping force in press units279.30tf

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Four 120 cm2 parts. The inputs, in the units selected above:

InputValue
Projected area of one part120.00 cm²
Number of cavities4.0000 -
Projected area of the runner20.000 cm²
Mean cavity pressure (gauge)35.000 MPa
Safety margin15.000 %

Applying the formula below gives:

ResultValue
Total projected area500.00 cm²
Clamping force2,012.5 kN
Clamping force in press units205.22 tf

Open this example in the calculator and change any input.

Formula

\(F = (n A_p + A_r)\, p_c\, (1 + k)\)

Variables

Symbol Meaning SI unit
\(A_p\) Projected area of one part m²
\(n\) Number of cavities -
\(A_r\) Projected area of the runner m²
\(p_c\) Mean cavity pressure (gauge) Pa
\(k\) Safety margin -
\(A\) Total projected area m²
\(F\) Clamping force N
\(P\) Clamping force in press units N

Method and standards

Force balance.

Where it is used

  • Machine selection.
  • Tool quoting.

Common mistakes

  • Part surface area instead of projected area.
  • Forgetting the runner.

Assumptions and limits

  • Uniform mean cavity pressure (gauge; the atmosphere acts on both sides of the mould).
  • The press rating is shown in tonne-force (kip in FPS).

References

  • F = projected area × cavity pressure × (1 + margin)

Questions and answers

Four 120 cm² parts and 20 cm² of runner at 35 MPa?

About 2012 kN: a 205 t machine.

Thin walls?

Long flows in thin walls need much higher pressure.

Flash?

Too little clamp lets the tool open: flash.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators