Worked example
Example: Sand 100 µm in air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Particle diameter | 100.00 µm |
| Particle density | 2,500.0 kg/m³ |
| Fluid density | 1.2000 kg/m³ |
| Fluid dynamic viscosity | 1.8000e-05 Pa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Terminal velocity | 0.53597 m/s |
| Particle Reynolds number | 3.5732 |
| Drag coefficient | 9.4781 |
| Stokes-law velocity (valid for Re below about 0.3) | 0.75632 m/s |
Open this example in the calculator and change any input.
Formula
\(C_D\, Re^2 = \frac{4 g d_p^3 \rho_f (\rho_p - \rho_f)}{3 \mu^2}\)
\(C_D = \frac{24}{Re}\left(1 + 0.1806\, Re^{0.6459}\right) + \frac{0.4251}{1 + 6880.95/Re}\)
\(v_t = \frac{Re\, \mu}{\rho_f d_p}, \quad v_{St} = \frac{g d_p^2 (\rho_p - \rho_f)}{18 \mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | particle diameter | m |
| \(\rho_p\) | particle density | kg/m³ |
| \(\rho_f\) | fluid density | kg/m³ |
| \(\mu\) | fluid dynamic viscosity | Pa·s |
| \(g\) | standard gravity | m/s² |
| \(v_t\) | terminal velocity | m/s |
| \(Re\) | particle Reynolds number | - |
| \(C_D\) | drag coefficient | - |
| \(v_{St}\) | Stokes-law velocity | m/s |
Method and standards
At terminal velocity weight less buoyancy equals drag. The product C_D Re² depends only on the particle and fluid, so Re is found from it with the Haider–Levenspiel (1989) sphere correlation, valid up to Re 2.6×10⁵, and the velocity follows. The Stokes value is shown for comparison.
Where it is used
- Checking carry-over from fluidised beds and furnaces.
- Sizing settling chambers and drop-out boxes.
- Estimating ash deposition in low-velocity ducts.
Common mistakes
- Using Stokes' law at Reynolds numbers well above 1.
- Using bulk density for the particle density.
- Ignoring that irregular particles settle more slowly than spheres.
Assumptions and limits
- Single smooth sphere in still, unbounded fluid; sphericity is not an input, and irregular particles settle more slowly than the value shown.
- No hindered settling (dilute suspension).
- Re up to 2.6×10⁵.
References
- Haider and Levenspiel (1989)
- Powder Technology 58
- eq. 6
- Stokes' law
Questions and answers
How fast does 100 µm sand settle in air?
About 0.54 m/s. Stokes' law would say 0.76 m/s, but at Re about 3.6 the drag is already higher than Stokes allows.
When is Stokes' law good enough?
Below a particle Reynolds number of about 0.3; fine fly ash of 20 µm settles at about 16 mm/s, close to the Stokes value.
Why does this matter for boilers?
It sets which particles a gas stream carries out of a furnace, bed or duct, and how fast ash settles in hoppers and ducts.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.