Worked example
Example: 250 mm mercury under water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reading (difference in levels or length along an inclined tube) | 250.00 mm |
| Density of the manometer liquid | 13,546 kg/m³ |
| Density of the fluid above it | 998.00 kg/m³ |
| Tube angle from horizontal (90° for a vertical U-tube) | 90.000 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure difference g h sin θ (ρ_m − ρ_f) | 30.763 kPa |
| Vertical height difference | 250.00 mm |
| Equivalent column of water at 1000 kg/m³ | 3,137.0 mm |
Open this example in the calculator and change any input.
Formula
\(\Delta p = g\, h \sin\theta\, (\rho_m - \rho_f)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h\) | Reading (difference in levels or length along an inclined tube) | m |
| \(\rho_m\) | Density of the manometer liquid | kg/m³ |
| \(\rho_f\) | Density of the fluid above it | kg/m³ |
| \(\theta\) | Tube angle from horizontal (90° for a vertical U-tube) | rad |
| \(\Delta p\) | Pressure difference g h sin θ (ρ_m − ρ_f) | Pa |
| \(h_v\) | Vertical height difference | m |
| \(h_{wc}\) | Equivalent column of water at 1000 kg/m³ | m |
Method and standards
Hydrostatics.
Where it is used
- Orifice and filter DP checks.
- Calibration of DP transmitters.
Common mistakes
- Forgetting the process fluid leg.
- Reading only one leg of a U-tube.
Assumptions and limits
- Static liquids. For a well-type inclined manometer the reservoir level also falls: multiply by (1 + a/(A sin θ)) with a/A the tube-to-well area ratio; this correction is not applied.
References
- Hydrostatics of a U-tube manometer
Questions and answers
250 mm of mercury under water?
30.8 kPa.
Why subtract the process fluid density?
The same fluid fills the other leg above the meniscus.
Why incline the tube?
A small vertical rise becomes a long, readable length.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.