FireCADCalc

U-Tube Manometer Pressure Difference

Pressure difference from a U-tube manometer reading with a manometer liquid and a process fluid above it, and for an inclined-tube manometer.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 250 mm mercury under waterWater manometer in air, 150 mmInclined 20°, 120 mm of gauge oil 850 in air

Mercury 13 546 kg/m³ at 20 °C; water 998.

Results

Pressure difference g h sin θ (ρ_m − ρ_f)30.763kPa
Vertical height difference250.00mm
Equivalent column of water at 1000 kg/m³3,137.0mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 mm mercury under water. The inputs, in the units selected above:

InputValue
Reading (difference in levels or length along an inclined tube)250.00 mm
Density of the manometer liquid13,546 kg/m³
Density of the fluid above it998.00 kg/m³
Tube angle from horizontal (90° for a vertical U-tube)90.000 °

Applying the formula below gives:

ResultValue
Pressure difference g h sin θ (ρ_m − ρ_f)30.763 kPa
Vertical height difference250.00 mm
Equivalent column of water at 1000 kg/m³3,137.0 mm

Open this example in the calculator and change any input.

Formula

\(\Delta p = g\, h \sin\theta\, (\rho_m - \rho_f)\)

Variables

Symbol Meaning SI unit
\(h\) Reading (difference in levels or length along an inclined tube) m
\(\rho_m\) Density of the manometer liquid kg/m³
\(\rho_f\) Density of the fluid above it kg/m³
\(\theta\) Tube angle from horizontal (90° for a vertical U-tube) rad
\(\Delta p\) Pressure difference g h sin θ (ρ_m − ρ_f) Pa
\(h_v\) Vertical height difference m
\(h_{wc}\) Equivalent column of water at 1000 kg/m³ m

Method and standards

Hydrostatics.

Where it is used

  • Orifice and filter DP checks.
  • Calibration of DP transmitters.

Common mistakes

  • Forgetting the process fluid leg.
  • Reading only one leg of a U-tube.

Assumptions and limits

  • Static liquids. For a well-type inclined manometer the reservoir level also falls: multiply by (1 + a/(A sin θ)) with a/A the tube-to-well area ratio; this correction is not applied.

References

  • Hydrostatics of a U-tube manometer

Questions and answers

250 mm of mercury under water?

30.8 kPa.

Why subtract the process fluid density?

The same fluid fills the other leg above the meniscus.

Why incline the tube?

A small vertical rise becomes a long, readable length.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.