Worked example
Example: Water 10 m deep, open tank, 1 m². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid density | 1,000.0 kg/m³ |
| Depth below the free surface (head) | 10.000 m |
| Pressure on the free surface (absolute) | 101.33 kPa |
| Area (horizontal) at that depth, for the force | 1.0000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure from the liquid (gauge, above the surface pressure) | 98.067 kPa |
| Absolute pressure | 199.39 kPa |
| Force on the area from the liquid | 98.067 kN |
| Specific gravity (water at 4 °C = 1) | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(p_g = \rho\,g\,h \qquad p = p_0 + p_g \qquad F = p_g\,A \qquad SG = \frac{\rho}{\rho_{w,4\,°C}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | liquid density | kg/m³ |
| \(h\) | depth | m |
| \(p_0\) | surface pressure | Pa |
| \(A\) | area | m² |
| \(p_g\) | pressure from the liquid | Pa |
| \(p\) | absolute pressure | Pa |
| \(F\) | force on the area | N |
| \(SG\) | specific gravity | – |
| \(g\) | standard gravity | m/s² |
Method and standards
Hydrostatic equation at standard gravity; reference water density from IAPWS-IF97 at 4 °C and 1 atm.
Where it is used
- Tank and sump design.
- Level transmitter ranges.
- Pump suction head.
Common mistakes
- Mixing gauge and absolute pressure.
- Using water density for other liquids.
- Forgetting vapour pressure in closed hot tanks.
Assumptions and limits
- Incompressible liquid at rest; standard gravity.
- SG is against water at 4 °C (999.97 kg/m³). Petroleum practice uses water at 15.6 °C (60 °F), which gives SG about 0.1 % higher.
References
- Hydrostatics (p = ρ g h)
Questions and answers
What pressure does 10 m of water give?
98.07 kPa gauge (0.98 bar), 199.4 kPa absolute under 1 atm.
How do I convert head of oil?
Multiply by its density: 6 m of 950 kg/m³ oil gives 55.9 kPa.
Why specific gravity against 4 °C water?
That is the usual reference; water at 4 °C is at its densest, 1000.0 kg/m³.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.