FireCADCalc

Isentropic Compressible Flow: Mach Number Relations

Stagnation-to-static temperature, pressure and density ratios and the area ratio A/A* of an ideal gas at a Mach number, from the ratio of specific heats.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Mach 0.6 in airMach 2 in airSteam-like γ 1.3, Mach 1

Results

Temperature ratio1.1500
Pressure ratio1.8324
Density ratio1.5934
Area ratio to the sonic throat1.0000
Critical pressure ratio0.54573

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Mach 0.6 in air. The inputs, in the units selected above:

InputValue
Mach number0.60000 -
Ratio of specific heats1.4000 -

Applying the formula below gives:

ResultValue
Temperature ratio1.0720
Pressure ratio1.2755
Density ratio1.1898
Area ratio to the sonic throat1.1882
Critical pressure ratio0.52828

Open this example in the calculator and change any input.

Formula

\(\frac{T_0}{T} = 1 + \frac{\gamma - 1}{2} M^2, \quad \frac{p_0}{p} = \left(\frac{T_0}{T}\right)^{\gamma/(\gamma - 1)}, \quad \frac{A}{A^*} = \frac{1}{M}\left[\frac{2}{\gamma + 1}\frac{T_0}{T}\right]^{\frac{\gamma + 1}{2(\gamma - 1)}}\)

Variables

Symbol Meaning SI unit
\(M\) Mach number -
\(\gamma\) Ratio of specific heats -
\(T_0/T\) Temperature ratio -
\(p_0/p\) Pressure ratio -
\(\rho_0/\rho\) Density ratio -
\(A/A^*\) Area ratio to the sonic throat -
\(p^*/p_0\) Critical pressure ratio -

Method and standards

Energy and isentropic relations for a perfect gas.

Where it is used

  • Nozzle and diffuser design.
  • Gas dynamics examinations.

Common mistakes

  • Using γ for steam from air.
  • Applying across shocks.

Assumptions and limits

  • Perfect gas, isentropic.

References

  • Isentropic flow of a perfect gas (Anderson, Modern Compressible Flow)

Questions and answers

What are the ratios at Mach 0.6 in air?

T₀/T 1.0720, p₀/p 1.2755, A/A* 1.1882.

What is the critical pressure ratio?

0.528 for air: below it, flow through a throat is choked.

When does compressibility matter?

Above about Mach 0.3, where density changes over 5 %.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.