Worked example
Example: Air leak, 3 mm at 7 bar(a), 20 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Upstream pressure (absolute) | 7.0000 bar |
| Upstream temperature | 20.000 °C |
| Orifice diameter | 3.0000 mm |
| Discharge coefficient | 0.62000 - |
| Ratio of specific heats | 1.4000 - |
| Molar mass | 28.960 kg/kmol |
| Downstream pressure (absolute) | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical pressure ratio | 0.52828 |
| Mass flow (choked, or subsonic when not choked) | 26.066 kg/h |
| Free air or gas at 0 °C, 101.325 kPa | 20.174 Nm³/h |
Open this example in the calculator and change any input.
Formula
\(\dot m = C_d A p_0 \sqrt{\frac{2\gamma}{(\gamma - 1) R T_0}\left[\left(\frac{p_b}{p_0}\right)^{2/\gamma} - \left(\frac{p_b}{p_0}\right)^{(\gamma + 1)/\gamma}\right]}\ \ \left(\frac{p_b}{p_0} > \frac{p^*}{p_0}\right)\) \(\dot m = C_d A p_0 \sqrt{\frac{\gamma}{R T_0}} \left(\frac{2}{\gamma + 1}\right)^{\frac{\gamma + 1}{2(\gamma - 1)}}, \quad \frac{p^*}{p_0} = \left(\frac{2}{\gamma + 1}\right)^{\frac{\gamma}{\gamma - 1}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_0\) | Upstream pressure (absolute) | Pa |
| \(T_0\) | Upstream temperature | K |
| \(d\) | Orifice diameter | m |
| \(C_d\) | Discharge coefficient | - |
| \(\gamma\) | Ratio of specific heats | - |
| \(M\) | Molar mass | kg/kmol |
| \(p_b\) | Downstream pressure (absolute) | Pa |
| \(p^*/p_0\) | Critical pressure ratio | - |
| \(\dot m\) | Mass flow (choked) | kg/s |
| \(Q_N\) | Free air or gas at 0 °C, 101.325 kPa | Nm³/s |
Method and standards
Sonic flow at the throat.
Where it is used
- Compressed air leak surveys.
- Relief and vent estimates.
Common mistakes
- Gauge pressure for p₀.
- Applying it when not choked.
Assumptions and limits
- Ideal gas, isentropic to the throat, constant γ; steam near saturation and high-pressure gases deviate by a few per cent.
- When not choked the subsonic isentropic nozzle flow is shown.
References
- Isentropic nozzle at sonic throat: ṁ = C_d A p₀ √(γ/(R T₀)) (2/(γ+1))^((γ+1)/(2(γ−1)))
Questions and answers
Air leak through a 3 mm hole at 7 bar(a) and 20 °C?
About 7.2 g/s, 20 Nm³/h, with C_d 0.62.
When is flow choked?
When the downstream pressure is below about 0.53 of upstream (air): then flow depends only on upstream conditions.
Why use it for leaks?
Plant air at 7 bar leaking to atmosphere is always choked.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.