FireCADCalc

Centrifugal Compressor Impeller: Pressure Ratio, Eye Angles, Tip Depth

Temperature rise, pressure ratio and power of a centrifugal compressor from tip speed, slip and power input factors, with eye vane angles and impeller tip depth.

Thermal power plantRefinery and petrochemical

Inputs

Examples: Turbocharger 1,500 rev/s, 0.08 m impeller, 0.4 kg/s, eta 0.75Process compressor 200 rev/s, 0.8 m, 20 kg/s, radial velocity 120 m/s

Accepted: 1 to 1.2
Accepted: 70 to 100 %
Accepted: 95.493 to 95,493 rpm
Accepted: 0.05 to 3 m
Accepted: 0.02 to 2 m
Accepted: 0 to 1.5 m
Accepted: 36 to 1,800,000 kg/h
Accepted: -73.15 to 126.85 °C
Accepted: 0.1 to 10 bar
Accepted: 50 to 100 %
Accepted: 0 to 400 m/s
Accepted: 0 to 100 %
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 1.2 to 1.67

Results

Radial vanes, axial inlet (no prewhirl), axial velocity uniform across the eye and found by iterating the continuity equation with static density. The impeller tip depth assumes the chosen share of the total loss occurs in the impeller.

Impeller tip speed376.99m/s
Stagnation temperature rise129.42K
Pressure ratio2.6675
Power52.028kW
Axial velocity at the eye258.93m/s
Vane inlet angle at the eye root (from tangential)74.731°
Vane inlet angle at the eye tip47.698°
Relative Mach number at the eye tip1.0693
Static pressure at the impeller tip1.3732bar
Impeller channel depth at the tip4.3869mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Turbocharger 1,500 rev/s, 0.08 m impeller, 0.4 kg/s, eta 0.75. The inputs, in the units selected above:

InputValue
Power input factor1.0400 -
Slip factor88.000 %
Rotational speed90,000 rpm
Impeller tip diameter0.080000 m
Eye tip diameter0.050000 m
Eye root (hub) diameter0.015000 m
Air mass flow1,440.0 kg/h
Inlet stagnation temperature26.850 °C
Inlet stagnation pressure1.0000 bar
Isentropic efficiency75.000 %
Radial velocity at the tip (0 = equal to the eye axial velocity)0 m/s
Share of the total loss in the impeller50.000 %
Specific heat1.0050 kJ/(kg·K)
Ratio of specific heats1.4000 -

Applying the formula below gives:

ResultValue
Impeller tip speed376.99 m/s
Stagnation temperature rise129.42 K
Pressure ratio2.6675
Power52.028 kW
Axial velocity at the eye258.93 m/s
Vane inlet angle at the eye root (from tangential)74.731 °
Vane inlet angle at the eye tip47.698 °
Relative Mach number at the eye tip1.0693
Static pressure at the impeller tip1.3732 bar
Impeller channel depth at the tip4.3869 mm

Open this example in the calculator and change any input.

Formula

\(U = \pi D_2N, \quad T_{03} - T_{01} = \frac{\psi\sigma U^2}{c_p}, \quad \frac{p_{03}}{p_{01}} = \left[1 + \frac{\eta_c(T_{03} - T_{01})}{T_{01}}\right]^{\gamma/(\gamma - 1)}\)

\(\dot m = \rho_1A_1C_{a1}, \quad \alpha = \tan^{-1}\frac{C_{a1}}{U_{eye}}, \quad b_2 = \frac{\dot m}{\rho_2C_{r2}\pi D_2}\)

Variables

Symbol Meaning SI unit
\(\psi\) Power input factor -
\(\sigma\) Slip factor -
\(N\) Rotational speed rad/s
\(D_2\) Impeller tip diameter m
\(D_{et}\) Eye tip diameter m
\(D_{er}\) Eye root (hub) diameter m
\(\dot m\) Air mass flow kg/s
\(T_{01}\) Inlet stagnation temperature K
\(p_{01}\) Inlet stagnation pressure Pa
\(\eta_c\) Isentropic efficiency -
\(C_{r2}\) Radial velocity at the tip (0 = equal to the eye axial velocity) m/s
\(f_{imp}\) Share of the total loss in the impeller -
\(c_p\) Specific heat J/(kg·K)
\(\gamma\) Ratio of specific heats -
\(U\) Impeller tip speed m/s
\(T_{03} - T_{01}\) Stagnation temperature rise K
\(p_{03}/p_{01}\) Pressure ratio -
\(P\) Power W
\(C_{a1}\) Axial velocity at the eye m/s
\(\alpha_{root}\) Vane inlet angle at the eye root (from tangential) rad
\(\alpha_{tip}\) Vane inlet angle at the eye tip rad
\(M_{rel,tip}\) Relative Mach number at the eye tip -
\(p_2\) Static pressure at the impeller tip Pa
\(b_2\) Impeller channel depth at the tip m

Method and standards

Centrifugal compressor work and continuity at eye and tip.

Where it is used

  • Preliminary design of turbocharger and gas turbine compressors.
  • Checking impeller proportions.

Common mistakes

  • Using stagnation density at the eye.
  • Forgetting slip when computing work.

Assumptions and limits

  • Radial-vaned impeller, axial inlet, perfect gas with constant c_p.

Questions and answers

What are the power input and slip factors?

Slip (σ ≈ 0.9) reduces the whirl the impeller gives the air below the tip speed; the power input factor (ψ ≈ 1.04) adds the work lost to disc friction and windage, which heats the air without raising pressure.

Why check the eye tip Mach number?

Above about 0.8–0.9 relative Mach number shock losses grow; prewhirl vanes or a smaller eye tip diameter reduce it.

What do the defaults represent?

An illustrative case: Turbocharger 1,500 rev/s, 0.08 m impeller, 0.4 kg/s, eta 0.75. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), secs. 4.2 and 4.4, Example 4.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.