FireCADCalc

Compressed Air Pressure Dew Point to Atmospheric Dew Point

Atmospheric dew or frost point, vapour pressure and water content of compressed air from its pressure dew point and line pressure, over water and over ice.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)Air compressor and receiver

Inputs

Examples: 8 bar(g), PDP 3 °C (refrigerant dryer)7 bar(g), PDP −40 °C (desiccant dryer)10 bar(g), PDP −20 °C, site at 0.95 bar

Results

Below 0 °C the dew point is taken over ice (frost point, IAPWS R14-08); above it over water (IAPWS-IF97). Ideal gas, no enhancement factor.

Water vapour partial pressure in the line758.08Pa
Dew or frost point after expansion to atmosphere-21.983°C
Water per kg of dry air0.52353g/kg
Water per normal m³ of dry air0.67657g/Nm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 bar(g), PDP 3 °C (refrigerant dryer). The inputs, in the units selected above:

InputValue
Line pressure8.0000 bar g
Pressure dew point3.0000 °C
Atmospheric pressure1.0132 bar

Applying the formula below gives:

ResultValue
Water vapour partial pressure in the line758.08 Pa
Dew or frost point after expansion to atmosphere-21.983 °C
Water per kg of dry air0.52353 g/kg
Water per normal m³ of dry air0.67657 g/Nm³

Open this example in the calculator and change any input.

Formula

\(p_v = p_{sat}(T_{PDP})\)

\(p_{sat}(T_{ADP}) = p_v \frac{p_a}{p}\)

\(W = \frac{M_w}{M_a} \frac{p_v}{p - p_v}\)

Variables

Symbol Meaning SI unit
\(p\) Line pressure Pa
\(T_{PDP}\) Pressure dew point K
\(p_a\) Atmospheric pressure Pa
\(p_v\) Water vapour partial pressure in the line Pa
\(T_{ADP}\) Dew or frost point after expansion to atmosphere K
\(W\) Water per kg of dry air kg/kg
\(c_w\) Water per normal m³ of dry air kg/m³
\(p_{sat}\) Saturation pressure over water or ice Pa
\(M_w / M_a\) Molar mass ratio water to dry air (0.622) -

Method and standards

Water vapour keeps its mole fraction when air expands, so its partial pressure falls in proportion to total pressure. Saturation is over liquid water (IAPWS-IF97) above 0.01 °C and over ice (IAPWS R14-08) below.

Where it is used

  • Comparing dryers rated on different bases.
  • Choosing a dryer for an ISO 8573-1 class.
  • Checking whether lines outdoors can freeze.

Common mistakes

  • Comparing a pressure dew point with an atmospheric one.
  • Entering gauge pressure as absolute.
  • Using dew point over water below 0 °C.

Assumptions and limits

  • Ideal gas, no enhancement factor (at 10 bar and above the water content is under-estimated by roughly half a per cent).
  • A line pressure entered as gauge is turned into absolute with the standard atmosphere; at altitude enter it as absolute (a note appears when p_a differs from 1.01325 bar).
  • Dew point between −100 °C and 100 °C.

References

  • IAPWS-IF97 saturation over water
  • IAPWS R14-08(2011) sublimation pressure over ice
  • ISO 8573-1 dew point classes (definitions)

Questions and answers

What is a 3 °C pressure dew point at 8 bar(g) in atmospheric terms?

The vapour pressure 758 Pa expands to 85 Pa at 1 atm, a frost point of −22 °C.

Why does it matter which one a dryer states?

A refrigerant dryer's 3 °C PDP and a desiccant dryer's −40 °C PDP look close in ADP terms, but the water content differs by a factor of fifty.

Is the dew point over ice or water?

Below 0 °C this page uses ice (a frost point), as hygrometers and ISO 8573 do.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.