Worked example
Example: Air 1 to 30 bar(a), 3 stages. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Suction pressure (absolute) | 1.0132 bar |
| Final discharge pressure (absolute) | 30.000 bar |
| Number of stages | 3.0000 - |
| First-stage suction temperature | 30.000 °C |
| Gas temperature after each intercooler | 40.000 °C |
| Isentropic efficiency per stage | 80.000 % |
| Ratio of specific heats | 1.4000 - |
| Molar mass | 28.960 kg/kmol |
| Mass flow | 3,600.0 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure ratio per stage | 3.0936 |
| Discharge pressure of stage 1 | 3.1346 bar |
| Discharge temperature of stage 1 | 174.30 °C |
| Discharge temperature of later stages | 189.06 °C |
| Total shaft power | 444.58 kW |
| Duty of each intercooler | 134.96 kW |
| Total intercooler duty | 284.74 kW |
Open this example in the calculator and change any input.
Formula
\(r = \left(\frac{p_2}{p_1}\right)^{1/N}, \quad T_d = T_s + \frac{T_s\left(r^{(\gamma - 1)/\gamma} - 1\right)}{\eta_s}, \quad P = \dot mc_p\sum(T_d - T_s), \quad Q_{ic} = \dot mc_p(T_d - T_{ic})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Suction pressure (absolute) | Pa |
| \(p_2\) | Final discharge pressure (absolute) | Pa |
| \(N\) | Number of stages | - |
| \(T_1\) | First-stage suction temperature | K |
| \(T_{ic}\) | Gas temperature after each intercooler | K |
| \(\eta_s\) | Isentropic efficiency per stage | - |
| \(\gamma\) | Ratio of specific heats | - |
| \(M\) | Molar mass | kg/kmol |
| \(\dot m\) | Mass flow | kg/s |
| \(r\) | Pressure ratio per stage | - |
| \(p_{i,1}\) | Discharge pressure of stage 1 | Pa |
| \(T_{d,1}\) | Discharge temperature of stage 1 | K |
| \(T_{d,n}\) | Discharge temperature of later stages | K |
| \(P\) | Total shaft power | W |
| \(Q_{ic}\) | Duty of each intercooler | W |
| \(Q_{ic,total}\) | Total intercooler duty | W |
Method and standards
Ideal-gas staged compression.
Where it is used
- Air and process gas compressor checks.
- Intercooler and cooling-water sizing.
Common mistakes
- Gauge pressures.
- Forgetting interstage pressure drop.
Assumptions and limits
- Ideal gas; constant c_p; equal ratios.
References
- Ideal-gas staged compression with equal pressure ratios (definitions; Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 10, compressors)
Questions and answers
Why equal pressure ratios?
With full intercooling back to the same temperature, equal ratios give the least total work.
Where does the intercooler heat go?
To cooling water; it is about the same as the stage work, a good source of low-grade heat.
What do the defaults give?
Air 1 to 30 bar(a) in three stages: ratio 3.1 per stage and about 174 °C stage-1 discharge at 80 % efficiency.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.