FireCADCalc

Air Receiver Size (Compressed Air Tank)

Volume of a compressed-air receiver to supply a demand for a set time while the pressure falls between two limits, by the isothermal storage equation.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserTank and drumAir compressor and receiver

Inputs

Examples: 10 m³/min for 1 min, 8 to 6 bar gStandby start: 25 m³/min for 30 s, 7.5 to 6.5 bar gInstrument air 2 m³/min for 10 min, 7 to 4.5 bar g

The demand not met by the compressors during the time: a peak above their output, or the full demand while a standby compressor starts.

Results

Isothermal: the air in the receiver stays at room temperature. Choose the next standard size up.

Receiver volume5.0663m³
Free air released10.000m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m³/min for 1 min, 8 to 6 bar g. The inputs, in the units selected above:

InputValue
Air drawn from the receiver (free air)10.000 m³/min
Time the receiver must supply it1.0000 min
Pressure at the start (cut-out)8.0000 bar g
Lowest acceptable pressure6.0000 bar g
Atmospheric pressure (absolute)101.33 kPa

Applying the formula below gives:

ResultValue
Receiver volume5.0663 m³
Free air released10.000 m³

Open this example in the calculator and change any input.

Formula

\(V = \frac{\dot V_a\,t\,p_a}{p_1 - p_2} \qquad V_a = \dot V_a\,t\)

Variables

Symbol Meaning SI unit
\(\dot V_a\) free air drawn from the receiver m³/s
\(t\) time s
\(p_1\) start pressure Pa
\(p_2\) lowest pressure Pa
\(p_a\) atmospheric pressure Pa
\(V\) receiver volume m³
\(V_a\) free air released m³

Method and standards

Boyle's law at constant temperature between the two receiver pressures.

Where it is used

  • Plant and instrument air receivers.
  • Buffering compressor start-up.
  • Peak demand from blow-off or soot blowers.

Common mistakes

  • Using gauge pressures for p_a.
  • Forgetting the dryer's own pressure drop.
  • Undersizing for load–unload cycling.

Assumptions and limits

  • Isothermal; leaks during the time not included. For a fast drawdown (close to adiabatic) the volume needed is up to about 1.4 times larger.

References

  • Isothermal ideal-gas storage equation

Questions and answers

What receiver supplies 10 m³/min for a minute between 8 and 6 bar g?

5.07 m³ at 1.013 bar atmospheric: it releases 10 m³ of free air in that minute.

Why isothermal?

Air in a receiver stays near room temperature during slow draw-off. A fast draw-off is closer to adiabatic: the air cools as it expands, the pressure falls faster, and a larger receiver is needed (by up to the isentropic exponent, about 1.4 times).

Do I add the compressor output?

Enter only the demand the compressors cannot meet during the time.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.