Examples: 20 m³/min FAD to 7 bar g, 2 stages, 80 %10 m³/min to 7 bar g, single stage, 75 %Gas 5 m³/min, 2 bar(a) to 40 bar(a), k 1.3, 3 stages, 78 %

1.4 for air; about 1.3 for natural gas and CO₂.

Results

Shaft power101.57kW
Ideal adiabatic power81.257kW
Isothermal power69.844kW
Isothermal efficiency68.764%
Pressure ratio per stage2.8122
Specific power (kW per m³/min of FAD)5.0785

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 m³/min FAD to 7 bar g, 2 stages, 80 %. The inputs, in the units selected above:

InputValue
Inlet volume flow at p₁ and T₁ (free air delivery for an air compressor)20.000 m³/min
Inlet pressure (absolute)1.0132 bar
Discharge pressure7.0000 bar g
Isentropic exponent1.4000 -
Number of stages2 stages, intercooled
Isentropic efficiency (shaft basis)80.000 %

Applying the formula below gives:

ResultValue
Shaft power101.57 kW
Ideal adiabatic power81.257 kW
Isothermal power69.844 kW
Isothermal efficiency68.764 %
Pressure ratio per stage2.8122
Specific power (kW per m³/min of FAD)5.0785

Open this example in the calculator and change any input.

Formula

\(r_s = \left(\frac{p_2}{p_1}\right)^{1/z} \qquad P_{is} = z\,\frac{k}{k-1}\,p_1 \dot V_1\left(r_s^{(k-1)/k} - 1\right) \qquad P_{sh} = \frac{P_{is}}{\eta_{is}}\)

\(P_{iso} = p_1 \dot V_1 \ln\frac{p_2}{p_1} \qquad \eta_{iso} = \frac{P_{iso}}{P_{sh}} \qquad SP = \frac{P_{sh}}{\dot V_1}\)

Variables

Symbol Meaning SI unit
\(\dot V_1\) Inlet volume flow at p₁ and T₁ (free air delivery for an air compressor) m³/s
\(p_1\) inlet pressure Pa
\(p_2\) discharge pressure Pa
\(k\) isentropic exponent –
\(z\) number of stages –
\(\eta_{is}\) isentropic efficiency (shaft) –
\(P_{sh}\) shaft power W
\(P_{is}\) ideal adiabatic power W
\(P_{iso}\) isothermal power W
\(\eta_{iso}\) isothermal efficiency –
\(r_s\) pressure ratio per stage –
\(SP\) specific power kW per m³/min

Method and standards

Ideal-gas compression with equal pressure ratios per stage and perfect intercooling to inlet temperature; shaft power from the isentropic efficiency.

Where it is used

  • Sizing compressor motors.
  • Comparing compressor offers by specific power.
  • Energy audits of compressed-air systems.

Common mistakes

  • Using gauge pressures in the ratio.
  • Comparing specific power at different discharge pressures.
  • Forgetting dryer and cooler pressure drops.

Assumptions and limits

  • Ideal gas; equal stage ratios; perfect intercooling; motor and drive losses not included.
  • V̇₁ is the volume flow at the inlet pressure and temperature (for an air compressor, its free air delivery to ISO 1217).
  • A discharge pressure entered as gauge is converted with the standard atmosphere; when p₁ is not 1.01325 bar enter it as absolute (a note appears).

References

  • Thermodynamics of ideal-gas compression (isothermal and isentropic)

Questions and answers

How much power does 20 m³/min to 7 bar g take?

With two intercooled stages at 80 % isentropic efficiency: 101.6 kW at the shaft (81.3 kW ideal adiabatic, 69.8 kW isothermal), or 5.08 kW per m³/min.

Why stage a compressor?

Intercooling between stages brings the work closer to isothermal and keeps discharge temperatures down.

What is free air delivery?

The delivered air expressed as a volume at the compressor inlet conditions.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.