Worked example
Example: 20 m³/min FAD to 7 bar g, 2 stages, 80 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet volume flow at p₁ and T₁ (free air delivery for an air compressor) | 20.000 m³/min |
| Inlet pressure (absolute) | 1.0132 bar |
| Discharge pressure | 7.0000 bar g |
| Isentropic exponent | 1.4000 - |
| Number of stages | 2 stages, intercooled |
| Isentropic efficiency (shaft basis) | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shaft power | 101.57 kW |
| Ideal adiabatic power | 81.257 kW |
| Isothermal power | 69.844 kW |
| Isothermal efficiency | 68.764 % |
| Pressure ratio per stage | 2.8122 |
| Specific power (kW per m³/min of FAD) | 5.0785 |
Open this example in the calculator and change any input.
Formula
\(r_s = \left(\frac{p_2}{p_1}\right)^{1/z} \qquad P_{is} = z\,\frac{k}{k-1}\,p_1 \dot V_1\left(r_s^{(k-1)/k} - 1\right) \qquad P_{sh} = \frac{P_{is}}{\eta_{is}}\)
\(P_{iso} = p_1 \dot V_1 \ln\frac{p_2}{p_1} \qquad \eta_{iso} = \frac{P_{iso}}{P_{sh}} \qquad SP = \frac{P_{sh}}{\dot V_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_1\) | Inlet volume flow at p₁ and T₁ (free air delivery for an air compressor) | m³/s |
| \(p_1\) | inlet pressure | Pa |
| \(p_2\) | discharge pressure | Pa |
| \(k\) | isentropic exponent | – |
| \(z\) | number of stages | – |
| \(\eta_{is}\) | isentropic efficiency (shaft) | – |
| \(P_{sh}\) | shaft power | W |
| \(P_{is}\) | ideal adiabatic power | W |
| \(P_{iso}\) | isothermal power | W |
| \(\eta_{iso}\) | isothermal efficiency | – |
| \(r_s\) | pressure ratio per stage | – |
| \(SP\) | specific power | kW per m³/min |
Method and standards
Ideal-gas compression with equal pressure ratios per stage and perfect intercooling to inlet temperature; shaft power from the isentropic efficiency.
Where it is used
- Sizing compressor motors.
- Comparing compressor offers by specific power.
- Energy audits of compressed-air systems.
Common mistakes
- Using gauge pressures in the ratio.
- Comparing specific power at different discharge pressures.
- Forgetting dryer and cooler pressure drops.
Assumptions and limits
- Ideal gas; equal stage ratios; perfect intercooling; motor and drive losses not included.
- V̇₁ is the volume flow at the inlet pressure and temperature (for an air compressor, its free air delivery to ISO 1217).
- A discharge pressure entered as gauge is converted with the standard atmosphere; when p₁ is not 1.01325 bar enter it as absolute (a note appears).
References
- Thermodynamics of ideal-gas compression (isothermal and isentropic)
Questions and answers
How much power does 20 m³/min to 7 bar g take?
With two intercooled stages at 80 % isentropic efficiency: 101.6 kW at the shaft (81.3 kW ideal adiabatic, 69.8 kW isothermal), or 5.08 kW per m³/min.
Why stage a compressor?
Intercooling between stages brings the work closer to isothermal and keeps discharge temperatures down.
What is free air delivery?
The delivered air expressed as a volume at the compressor inlet conditions.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.