Worked example
Example: Single stage 35 °C to 7 bar g, 80 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet temperature (each stage, after intercooling) | 35.000 °C |
| Inlet pressure (absolute) | 1.0132 bar |
| Final discharge pressure | 7.0000 bar g |
| Isentropic exponent | 1.4000 - |
| Number of stages | 1 stage |
| Isentropic efficiency of the stage | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual discharge temperature | 345.27 °C |
| Ideal (isentropic) discharge temperature | 283.22 °C |
| Temperature rise per stage | 310.27 K |
| Pressure ratio per stage | 7.9085 |
Open this example in the calculator and change any input.
Formula
\(r_s = \left(\frac{p_2}{p_1}\right)^{1/z} \qquad T_{2s} = T_1\,r_s^{(k-1)/k} \qquad T_2 = T_1\left[1 + \frac{r_s^{(k-1)/k} - 1}{\eta_{is}}\right] \qquad \Delta T = T_2 - T_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | inlet temperature (each stage) | K |
| \(p_1\) | inlet pressure | Pa |
| \(p_2\) | final discharge pressure | Pa |
| \(k\) | isentropic exponent | – |
| \(z\) | number of stages | – |
| \(\eta_{is}\) | stage isentropic efficiency | – |
| \(T_2\) | actual discharge temperature | K |
| \(T_{2s}\) | ideal discharge temperature | K |
| \(\Delta T\) | rise per stage | K |
| \(r_s\) | ratio per stage | – |
Method and standards
Isentropic ideal-gas relation with the stage isentropic efficiency defined on enthalpy (constant cp).
Where it is used
- Intercooler and aftercooler design.
- Checking compressor health from temperatures.
- Choosing the number of stages.
Common mistakes
- Using gauge pressure.
- Forgetting that oil-injected screws are cooled by the oil and run much cooler.
- Ignoring a fouled intercooler.
Assumptions and limits
- Dry, oil-free compression; constant specific heat.
- Oil-injected screw compressors discharge far cooler (typically 80–100 °C) because the injected oil absorbs the heat: this dry adiabatic value does not apply to them. The 200 °C warning is for lubricated reciprocating machines.
References
- Thermodynamics of ideal-gas compression (isentropic)
Questions and answers
How hot is air after one stage to 7 bar g?
From 35 °C at 80 % efficiency: 345 °C (283 °C ideal). Two intercooled stages bring it down to about 167 °C.
Why does discharge temperature matter?
High temperature carbonises oil and is a fire risk in lubricated compressors and receivers.
What exponent for air?
1.4; about 1.3 for natural gas and CO₂.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.