FireCADCalc

Compressor Discharge Temperature

Gas temperature leaving each compressor stage from inlet temperature, pressure ratio, isentropic exponent and stage efficiency, ideal and actual.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserAir compressor and receiver

Inputs

Examples: Single stage 35 °C to 7 bar g, 80 %Two stages to 7 bar g, 35 °C, 80 %Gas k 1.3, 30 °C, 5 to 25 bar(a), 1 stage, 75 %

1.4 for air; about 1.3 for natural gas and CO₂.

Results

Discharge above 200 °C: lubricated compressors risk oil carbonisation and fire; add a stage or cool better.

Actual discharge temperature345.27°C
Ideal (isentropic) discharge temperature283.22°C
Temperature rise per stage310.27K
Pressure ratio per stage7.9085

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Single stage 35 °C to 7 bar g, 80 %. The inputs, in the units selected above:

InputValue
Inlet temperature (each stage, after intercooling)35.000 °C
Inlet pressure (absolute)1.0132 bar
Final discharge pressure7.0000 bar g
Isentropic exponent1.4000 -
Number of stages1 stage
Isentropic efficiency of the stage80.000 %

Applying the formula below gives:

ResultValue
Actual discharge temperature345.27 °C
Ideal (isentropic) discharge temperature283.22 °C
Temperature rise per stage310.27 K
Pressure ratio per stage7.9085

Open this example in the calculator and change any input.

Formula

\(r_s = \left(\frac{p_2}{p_1}\right)^{1/z} \qquad T_{2s} = T_1\,r_s^{(k-1)/k} \qquad T_2 = T_1\left[1 + \frac{r_s^{(k-1)/k} - 1}{\eta_{is}}\right] \qquad \Delta T = T_2 - T_1\)

Variables

Symbol Meaning SI unit
\(T_1\) inlet temperature (each stage) K
\(p_1\) inlet pressure Pa
\(p_2\) final discharge pressure Pa
\(k\) isentropic exponent –
\(z\) number of stages –
\(\eta_{is}\) stage isentropic efficiency –
\(T_2\) actual discharge temperature K
\(T_{2s}\) ideal discharge temperature K
\(\Delta T\) rise per stage K
\(r_s\) ratio per stage –

Method and standards

Isentropic ideal-gas relation with the stage isentropic efficiency defined on enthalpy (constant cp).

Where it is used

  • Intercooler and aftercooler design.
  • Checking compressor health from temperatures.
  • Choosing the number of stages.

Common mistakes

  • Using gauge pressure.
  • Forgetting that oil-injected screws are cooled by the oil and run much cooler.
  • Ignoring a fouled intercooler.

Assumptions and limits

  • Dry, oil-free compression; constant specific heat.
  • Oil-injected screw compressors discharge far cooler (typically 80–100 °C) because the injected oil absorbs the heat: this dry adiabatic value does not apply to them. The 200 °C warning is for lubricated reciprocating machines.

References

  • Thermodynamics of ideal-gas compression (isentropic)

Questions and answers

How hot is air after one stage to 7 bar g?

From 35 °C at 80 % efficiency: 345 °C (283 °C ideal). Two intercooled stages bring it down to about 167 °C.

Why does discharge temperature matter?

High temperature carbonises oil and is a fire risk in lubricated compressors and receivers.

What exponent for air?

1.4; about 1.3 for natural gas and CO₂.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.