Compressed Air Pipe Pressure Drop

Pressure drop and velocity in a compressed air main from free air flow, line pressure and temperature, pipe size and equivalent length.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 m³/min at 8 bar(a), 2-in., 150 m30 m³/min at 7 bar(a), 3-in., 300 m

Results

Velocity above about 8 m/s in a main: expect noise and carry-over of condensate.

Air density in the line9.1934kg/m³
Velocity10.084m/s
Reynolds number261,561
Pressure drop0.26887bar
Drop as a share of line pressure3.3608%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m³/min at 8 bar(a), 2-in., 150 m. The inputs, in the units selected above:

InputValue
Free air flow (at 1.01325 bar, 20 °C)10.000 m³/min
Line pressure (absolute)8.0000 bar
Air temperature in the line30.000 °C
Pipe inside diameter52.500 mm
Equivalent length150.00 m
Roughness0.045000 mm

Applying the formula below gives:

ResultValue
Air density in the line9.1934 kg/m³
Velocity10.084 m/s
Reynolds number261,561
Pressure drop0.26887 bar
Drop as a share of line pressure3.3608 %

Open this example in the calculator and change any input.

Formula

\(\dot m = \rho_{ref}\dot V_{FAD}, \quad v = \frac{\dot m}{\rho\pi d^2/4}, \quad \Delta p = f_D\frac{L}{d}\frac{\rho v^2}{2}\)

Variables

Symbol Meaning SI unit
\(\dot V_{FAD}\) Free air flow (at 1.01325 bar, 20 °C) m³/s
\(p\) Line pressure (absolute) Pa
\(T\) Air temperature in the line K
\(d\) Pipe inside diameter m
\(L\) Equivalent length m
\(\varepsilon\) Roughness m
\(\rho\) Air density in the line kg/m³
\(v\) Velocity m/s
\(Re\) Reynolds number -
\(\Delta p\) Pressure drop Pa
\(\Delta p/p\) Drop as a share of line pressure -

Method and standards

Pipe friction at line density.

Where it is used

  • Compressed air ring mains.
  • Energy audits.

Common mistakes

  • Using free-air velocity.
  • Ignoring fittings in the equivalent length.

Assumptions and limits

  • Small drop relative to pressure; isothermal.
  • The free air flow is referred to 1.01325 bar and 20 °C. A compressor FAD to ISO 1217 is at the actual inlet conditions: convert it to this reference first (see the FAD altitude and temperature correction).
  • Relative roughness outside the range of the Colebrook equation is rejected.

References

  • Darcy–Weisbach with Colebrook (FireCAD engine); Sutherland air viscosity

Questions and answers

What drop is acceptable?

About 0.1 bar from compressor to the furthest user in a well-designed system; every extra bar of compression costs about 7 % more power.

Why use free air flow?

Compressors are rated in free air delivery; the actual volume in the pipe is smaller by the pressure ratio.

What do the defaults represent?

10 m³/min free air at 8 bar(a) in a 2-in. main, 150 m equivalent.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.