Worked example
Example: 10 m³/min at 8 bar(a), 2-in., 150 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Free air flow (at 1.01325 bar, 20 °C) | 10.000 m³/min |
| Line pressure (absolute) | 8.0000 bar |
| Air temperature in the line | 30.000 °C |
| Pipe inside diameter | 52.500 mm |
| Equivalent length | 150.00 m |
| Roughness | 0.045000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air density in the line | 9.1934 kg/m³ |
| Velocity | 10.084 m/s |
| Reynolds number | 261,561 |
| Pressure drop | 0.26887 bar |
| Drop as a share of line pressure | 3.3608 % |
Open this example in the calculator and change any input.
Formula
\(\dot m = \rho_{ref}\dot V_{FAD}, \quad v = \frac{\dot m}{\rho\pi d^2/4}, \quad \Delta p = f_D\frac{L}{d}\frac{\rho v^2}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_{FAD}\) | Free air flow (at 1.01325 bar, 20 °C) | m³/s |
| \(p\) | Line pressure (absolute) | Pa |
| \(T\) | Air temperature in the line | K |
| \(d\) | Pipe inside diameter | m |
| \(L\) | Equivalent length | m |
| \(\varepsilon\) | Roughness | m |
| \(\rho\) | Air density in the line | kg/m³ |
| \(v\) | Velocity | m/s |
| \(Re\) | Reynolds number | - |
| \(\Delta p\) | Pressure drop | Pa |
| \(\Delta p/p\) | Drop as a share of line pressure | - |
Method and standards
Pipe friction at line density.
Where it is used
- Compressed air ring mains.
- Energy audits.
Common mistakes
- Using free-air velocity.
- Ignoring fittings in the equivalent length.
Assumptions and limits
- Small drop relative to pressure; isothermal.
- The free air flow is referred to 1.01325 bar and 20 °C. A compressor FAD to ISO 1217 is at the actual inlet conditions: convert it to this reference first (see the FAD altitude and temperature correction).
- Relative roughness outside the range of the Colebrook equation is rejected.
References
- Darcy–Weisbach with Colebrook (FireCAD engine); Sutherland air viscosity
Questions and answers
What drop is acceptable?
About 0.1 bar from compressor to the furthest user in a well-designed system; every extra bar of compression costs about 7 % more power.
Why use free air flow?
Compressors are rated in free air delivery; the actual volume in the pipe is smaller by the pressure ratio.
What do the defaults represent?
10 m³/min free air at 8 bar(a) in a 2-in. main, 150 m equivalent.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.