FireCADCalc

Water Condensed from Compressed Air (After-Cooler and Dryer)

Water entering with intake air and the amounts condensed in the after-cooler and dryer, from intake humidity, line pressure and pressure dew points.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Desiccant dryer, 10 m³/min, 35 °C 70 %, 8 bar(a), 40 °C cooler, −40 °C PDP10 m³/min, 35 °C 70 %, 8 bar(a), 40 °C cooler, 3 °C PDPHumid monsoon 30 °C 90 %, 7 bar(a), 35 °C, 3 °C

Results

Free air delivery is taken at intake conditions here. Most water drops out in the after-cooler; drains must keep up with it or water carries into the mains.

Water entering with the air16.622kg/h
Condensed in the after-cooler12.794kg/h
Removed by the dryer3.4379kg/h
Total condensate per day (as water at 1 kg/L)389.57L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Desiccant dryer, 10 m³/min, 35 °C 70 %, 8 bar(a), 40 °C cooler, −40 °C PDP. The inputs, in the units selected above:

InputValue
Free air delivery10.000 m³/min
Intake temperature35.000 °C
Intake relative humidity70.000 %
Intake pressure101.33 kPa
Line pressure (absolute)8.0000 bar
After-cooler outlet temperature (saturated)40.000 °C
Dryer pressure dew point-40.000 °C

Applying the formula below gives:

ResultValue
Water entering with the air16.622 kg/h
Condensed in the after-cooler12.794 kg/h
Removed by the dryer3.8210 kg/h
Total condensate per day (as water at 1 kg/L)398.76 L

Open this example in the calculator and change any input.

Formula

\(\dot m_w = \dot m_a(W_0 - W_{sat}(p, T)), \quad W = \frac{M_w}{M_a}\frac{p_v}{p - p_v}\ (\approx 0.622\ldots)\)

Variables

Symbol Meaning SI unit
\(\dot V_{FAD}\) Free air delivery m³/s
\(T_i\) Intake temperature K
\(\phi\) Intake relative humidity -
\(p_a\) Intake pressure Pa
\(p\) Line pressure (absolute) Pa
\(T_{ac}\) After-cooler outlet temperature (saturated) K
\(T_{pdp}\) Dryer pressure dew point (below 0 °C: over ice) K
\(\dot m_{w,in}\) Water entering with the air kg/s
\(\dot m_{ac}\) Condensed in the after-cooler kg/s
\(\dot m_{d}\) Removed by the dryer kg/s
\(\dot m_{day}\) Total condensate per day, as a volume of water at 1 000 kg/m³ m³

Method and standards

Humid-air mass balance.

Where it is used

  • Drain and oil–water separator sizing.
  • Dryer selection.

Common mistakes

  • Ignoring the after-cooler's share.
  • Using atmospheric dew point for pressure dew point.

Assumptions and limits

  • Saturated air at the cooler outlet.
  • Dew points below 0 °C (desiccant dryers) use saturation over ice (IAPWS R14-08); the water is then held by the desiccant rather than drained.
  • The daily total is shown as a volume of water at 1 000 kg/m³.

References

  • Humid-air saturation with IAPWS-IF97 (FireCAD engine) and mass balance (definitions)

Questions and answers

Why so much water?

Compression concentrates the intake's moisture; cooling the air back near ambient at 7 bar(g) squeezes most of it out.

Where does the condensate go?

Through drains on the after-cooler, receiver and filters; it often carries compressor oil and needs separation before discharge.

What do the defaults represent?

10 m³/min of humid 35 °C air compressed to 8 bar(a), after-cooled to 40 °C and dried to a 3 °C dew point.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.