Worked example
Example: 5 m³, 250 m³/h, atmosphere to 10 mbar; 10 min wanted. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume of the vessel and piping | 5.0000 m³ |
| Effective pumping speed at the vessel | 250.00 m³/h |
| Starting pressure (absolute) | 1,013.2 mbar |
| Target pressure (absolute) | 10.000 mbar |
| Time wanted (for the speed needed) | 10.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pump-down time (V/S) ln(p₁/p₂) | 5.5420 min |
| Pumping speed needed for the time wanted | 138.55 m³/h |
Open this example in the calculator and change any input.
Formula
\(t = \frac{V}{S}\ln\frac{p_1}{p_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Volume of the vessel and piping | m³ |
| \(S\) | Effective pumping speed at the vessel | m³/s |
| \(p_1\) | Starting pressure (absolute) | Pa |
| \(p_2\) | Target pressure (absolute) | Pa |
| \(t_w\) | Time wanted (for the speed needed) | s |
| \(t\) | Pump-down time (V/S) ln(p₁/p₂) | s |
| \(S_{req}\) | Pumping speed needed for the time wanted | m³/s |
Method and standards
Mass balance with constant volumetric speed.
Where it is used
- Vacuum dryers, condensers and evaporators.
- Pump selection.
Common mistakes
- Pump nameplate speed instead of effective speed.
- Ignoring leakage.
Assumptions and limits
Valid in the rough vacuum range (down to about 1 mbar); the page warns for lower targets, where outgassing and leakage set the time.
Rough vacuum, no gas load.
References
- Pump-down equation for constant pumping speed (vacuum technology texts)
Questions and answers
5 m³ from atmospheric to 10 mbar with 250 m³/h?
5.5 minutes.
Why logarithmic?
Each pass removes the same share of the remaining gas.
Why does it take longer in practice?
Leaks, outgassing and falling pump speed at low pressure.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.