FireCADCalc

Centrifugal Compressor Sizing: Head, Stages, Tip Speed and Power

Polytropic head, number of stages for a head per stage, impeller tip speed from a head coefficient, shaft speed, flow coefficients, discharge temperature and power.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Propane refrigeration 12,000 cfm, M 44.1, k 1.13, 20 to 200 psia

Accepted: 21.189 to 1,059,400 ft³/min
Accepted: 79.366 to 7,936,600 lb/h
Accepted: 2 to 200 kg/kmol
Accepted: -189.67 to 620.33 °F
Accepted: 1.4504 to 4,351.1 psi
Accepted: 1.4504 to 7,251.9 psi
Accepted: 1.05 to 1.67
Accepted: 50 to 95 %
Accepted: 0.3 to 1.5
Accepted: 5 to 100 kJ/kg
Accepted: 0.3 to 0.7
Accepted: 3.937 to 98.425 in
Accepted: 0 to 20 %

Results

The rules: about 10,000 ft·lbf/lbm (29.9 kJ/kg) of head per stage, head coefficient 0.48, at most eight stages per casing and a discharge temperature below about 475 °F. Flow coefficients of 0.01-0.10 (2-D impellers) or up to 0.15 (3-D) give good efficiency; read the efficiency from the maker's curve and repeat.

Pressure ratio10.000
Polytropic exponent1.1730
Polytropic head126.74kJ/kg
Number of stages5.0000
Head per stage25.347kJ/kg
Impeller tip speed753.93ft/s
Shaft speed5,759.6rpm
Inlet volume of the last stage2,495.6ft³/min
First-stage flow coefficient0.054042
Last-stage flow coefficient0.011239
Discharge temperature213.98°F
Shaft power3,343.9hp

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Propane refrigeration 12,000 cfm, M 44.1, k 1.13, 20 to 200 psia. The inputs, in the units selected above:

InputValue
Inlet volume flow12,000 ft³/min
Mass flow120,000 lb/h
Molar mass44.100 kg/kmol
Inlet temperature20.000 °F
Inlet pressure20.000 psi
Discharge pressure200.00 psi
Isentropic exponent1.1300 -
Polytropic efficiency78.000 %
Average compressibility0.92000 -
Maximum head per stage29.891 kJ/kg
Polytropic head coefficient0.48000 -
Impeller diameter30.000 in
Mechanical losses1.5000 %

Applying the formula below gives:

ResultValue
Pressure ratio10.000
Polytropic exponent1.1730
Polytropic head126.74 kJ/kg
Number of stages5.0000
Head per stage25.347 kJ/kg
Impeller tip speed753.93 ft/s
Shaft speed5,759.6 rpm
Inlet volume of the last stage2,495.6 ft³/min
First-stage flow coefficient0.054042
Last-stage flow coefficient0.011239
Discharge temperature213.98 °F
Shaft power3,343.9 hp

Open this example in the calculator and change any input.

Formula

\(\frac{n - 1}{n} = \frac{k - 1}{k\eta_p}, \quad H_p = Z\frac{R}{M}T_1\frac{n}{n - 1}\left(r_p^{\frac{n - 1}{n}} - 1\right), \quad z = \left\lceil\frac{H_p}{H_{stage}}\right\rceil\)

\(u_2 = \sqrt{\frac{H_p/z}{\mu_p}}, \quad N = \frac{u_2}{\pi d_2}, \quad Q_{ls} = Q_1\Big/\left(r_p^{(z-1)/z}\right)^{1/n}, \quad \delta = \frac{Q}{(\pi/4)d_2^2u_2}\)

Variables

Symbol Meaning SI unit
\(Q_1\) Inlet volume flow m³/s
\(w\) Mass flow kg/s
\(M\) Molar mass kg/kmol
\(T_1\) Inlet temperature K
\(P_1\) Inlet pressure Pa
\(P_2\) Discharge pressure Pa
\(k\) Isentropic exponent -
\(\eta_p\) Polytropic efficiency -
\(Z_{avg}\) Average compressibility -
\(H_{stage}\) Maximum head per stage J/kg
\(\mu_p\) Polytropic head coefficient -
\(d_2\) Impeller diameter m
\(f_m\) Mechanical losses -
\(r_p\) Pressure ratio -
\(n\) Polytropic exponent -
\(H_p\) Polytropic head J/kg
\(z\) Number of stages -
\(H_p/z\) Head per stage J/kg
\(u_2\) Impeller tip speed m/s
\(N\) Shaft speed rad/s
\(Q_{ls}\) Inlet volume of the last stage m³/s
\(\delta_1\) First-stage flow coefficient -
\(\delta_z\) Last-stage flow coefficient -
\(T_2\) Discharge temperature K
\(W\) Shaft power W

Method and standards

The centrifugal compressor sizing procedure.

Where it is used

  • Budget sizing and bid evaluation of process compressors.
  • Checking vendors' stage counts and speeds.

Common mistakes

  • Using the isentropic exponent in place of the polytropic one.
  • Forgetting to recompute with the efficiency read from the flow coefficient.

Assumptions and limits

  • Single uncooled section; ideal-gas head with average Z.

Questions and answers

Why a head coefficient of 0.48?

It is the polytropic head per stage divided by u₂²/g for a typical backward-leaning process impeller; Designers use it for first estimates.

What is the flow coefficient?

The inlet volume divided by (π/4)d₂²u₂; Designers write it as 700 Q/(N d₂³) with Q in cfm and d₂ in inches.

What do the defaults represent?

An illustrative case: Propane refrigeration 12,000 cfm, M 44.1, k 1.13, 20 to 200 psia. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Brown (Bloch and Hoefner), Compressors: Selection and Sizing, 3rd ed. (Gulf Professional Publishing, 2005), ch. 5, eqs. 5.12-5.19 and Example 5-2; ch. 2, eqs. 2.71-2.78

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.