Worked example
Example: Propane refrigeration 12,000 cfm, M 44.1, k 1.13, 20 to 200 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet volume flow | 12,000 ft³/min |
| Mass flow | 120,000 lb/h |
| Molar mass | 44.100 kg/kmol |
| Inlet temperature | 20.000 °F |
| Inlet pressure | 20.000 psi |
| Discharge pressure | 200.00 psi |
| Isentropic exponent | 1.1300 - |
| Polytropic efficiency | 78.000 % |
| Average compressibility | 0.92000 - |
| Maximum head per stage | 29.891 kJ/kg |
| Polytropic head coefficient | 0.48000 - |
| Impeller diameter | 30.000 in |
| Mechanical losses | 1.5000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure ratio | 10.000 |
| Polytropic exponent | 1.1730 |
| Polytropic head | 126.74 kJ/kg |
| Number of stages | 5.0000 |
| Head per stage | 25.347 kJ/kg |
| Impeller tip speed | 753.93 ft/s |
| Shaft speed | 5,759.6 rpm |
| Inlet volume of the last stage | 2,495.6 ft³/min |
| First-stage flow coefficient | 0.054042 |
| Last-stage flow coefficient | 0.011239 |
| Discharge temperature | 213.98 °F |
| Shaft power | 3,343.9 hp |
Open this example in the calculator and change any input.
Formula
\(\frac{n - 1}{n} = \frac{k - 1}{k\eta_p}, \quad H_p = Z\frac{R}{M}T_1\frac{n}{n - 1}\left(r_p^{\frac{n - 1}{n}} - 1\right), \quad z = \left\lceil\frac{H_p}{H_{stage}}\right\rceil\)
\(u_2 = \sqrt{\frac{H_p/z}{\mu_p}}, \quad N = \frac{u_2}{\pi d_2}, \quad Q_{ls} = Q_1\Big/\left(r_p^{(z-1)/z}\right)^{1/n}, \quad \delta = \frac{Q}{(\pi/4)d_2^2u_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_1\) | Inlet volume flow | m³/s |
| \(w\) | Mass flow | kg/s |
| \(M\) | Molar mass | kg/kmol |
| \(T_1\) | Inlet temperature | K |
| \(P_1\) | Inlet pressure | Pa |
| \(P_2\) | Discharge pressure | Pa |
| \(k\) | Isentropic exponent | - |
| \(\eta_p\) | Polytropic efficiency | - |
| \(Z_{avg}\) | Average compressibility | - |
| \(H_{stage}\) | Maximum head per stage | J/kg |
| \(\mu_p\) | Polytropic head coefficient | - |
| \(d_2\) | Impeller diameter | m |
| \(f_m\) | Mechanical losses | - |
| \(r_p\) | Pressure ratio | - |
| \(n\) | Polytropic exponent | - |
| \(H_p\) | Polytropic head | J/kg |
| \(z\) | Number of stages | - |
| \(H_p/z\) | Head per stage | J/kg |
| \(u_2\) | Impeller tip speed | m/s |
| \(N\) | Shaft speed | rad/s |
| \(Q_{ls}\) | Inlet volume of the last stage | m³/s |
| \(\delta_1\) | First-stage flow coefficient | - |
| \(\delta_z\) | Last-stage flow coefficient | - |
| \(T_2\) | Discharge temperature | K |
| \(W\) | Shaft power | W |
Method and standards
The centrifugal compressor sizing procedure.
Where it is used
- Budget sizing and bid evaluation of process compressors.
- Checking vendors' stage counts and speeds.
Common mistakes
- Using the isentropic exponent in place of the polytropic one.
- Forgetting to recompute with the efficiency read from the flow coefficient.
Assumptions and limits
- Single uncooled section; ideal-gas head with average Z.
Questions and answers
Why a head coefficient of 0.48?
It is the polytropic head per stage divided by u₂²/g for a typical backward-leaning process impeller; Designers use it for first estimates.
What is the flow coefficient?
The inlet volume divided by (π/4)d₂²u₂; Designers write it as 700 Q/(N d₂³) with Q in cfm and d₂ in inches.
What do the defaults represent?
An illustrative case: Propane refrigeration 12,000 cfm, M 44.1, k 1.13, 20 to 200 psia. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Brown (Bloch and Hoefner), Compressors: Selection and Sizing, 3rd ed. (Gulf Professional Publishing, 2005), ch. 5, eqs. 5.12-5.19 and Example 5-2; ch. 2, eqs. 2.71-2.78