FireCADCalc

Screw Compressor Sizing: Speed, Tip Mach Number, Power and Temperature

Twin-screw compressor displacement per revolution, rotor speed for an inlet volume, tip Mach number, adiabatic and shaft power and discharge temperature.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Hydrocarbon gas M 20, k 1.25, 6 in rotor

Accepted: 1.1811 to 59.055 in
Accepted: 0.5 to 3
Accepted: 0.5 to 10
Accepted: 2.1189 to 211,890 ft³/min
Accepted: 30 to 100 %
Accepted: 2 to 200 kg/kmol
Accepted: 1.05 to 1.67
Accepted: -99.67 to 440.33 °F
Accepted: 1.4504 to 725.19 psi
Accepted: 1.4504 to 1,450.4 psi
Accepted: 30 to 95 %
Accepted: 30 to 100 %
Accepted: 0 to 30 %

Results

Read the volumetric efficiency, the optimum tip Mach number and the adiabatic efficiency from the maker's or the curves for the pressure ratio and built-in volume ratio; efficiency falls when the tip speed departs from the optimum or the pressure ratio from the built-in one.

Displacement per revolution0.089646ft³
Displacement705.88ft³/min
Rotor speed7,874.1rpm
Rotor tip speed206.14ft/s
Speed of sound at inlet1,295.0ft/s
Rotor tip Mach number0.15918
Adiabatic power112.84hp
Shaft power120.74hp
Discharge temperature252.29°F

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hydrocarbon gas M 20, k 1.25, 6 in rotor. The inputs, in the units selected above:

InputValue
Rotor diameter6.0000 in
Length-to-diameter ratio1.6000 -
Lobe-geometry constant2.2310 -
Inlet volume flow600.00 ft³/min
Volumetric efficiency85.000 %
Molar mass of the gas20.000 kg/kmol
Isentropic exponent1.2500 -
Inlet temperature80.000 °F
Inlet pressure30.000 psi
Discharge pressure75.000 psi
Adiabatic efficiency70.000 %
Temperature-rise efficiency90.000 %
Mechanical losses (0.07 of adiabatic power)7.0000 %

Applying the formula below gives:

ResultValue
Displacement per revolution0.089646 ft³
Displacement705.88 ft³/min
Rotor speed7,874.1 rpm
Rotor tip speed206.14 ft/s
Speed of sound at inlet1,295.0 ft/s
Rotor tip Mach number0.15918
Adiabatic power112.84 hp
Shaft power120.74 hp
Discharge temperature252.29 °F

Open this example in the calculator and change any input.

Formula

\(Q_r = \frac{d^3(L/d)}{C}, \quad Q_d = \frac{Q_1}{E_v}, \quad N = \frac{Q_d}{Q_r}, \quad u = \pi dN, \quad a = \sqrt{kRT_1/M}\)

\(W_a = \frac{P_1Q_1\frac{k}{k-1}\left(r_p^{\frac{k-1}{k}} - 1\right)}{\eta_a}, \quad t_2 = t_1 + \frac{T_1\left(r_p^{\frac{k-1}{k}} - 1\right)}{\eta_a\eta_t}, \quad W_s = W_a(1 + f_m)\)

Variables

Symbol Meaning SI unit
\(d\) Rotor diameter m
\(L/d\) Length-to-diameter ratio -
\(C\) Lobe-geometry constant -
\(Q_1\) Inlet volume flow m³/s
\(E_v\) Volumetric efficiency -
\(M\) Molar mass of the gas kg/kmol
\(k\) Isentropic exponent -
\(T_1\) Inlet temperature K
\(P_1\) Inlet pressure Pa
\(P_2\) Discharge pressure Pa
\(\eta_a\) Adiabatic efficiency -
\(\eta_t\) Temperature-rise efficiency -
\(f_m\) Mechanical losses (0.07 of adiabatic power) -
\(Q_r\) Displacement per revolution m³
\(Q_d\) Displacement m³/s
\(N\) Rotor speed rad/s
\(u\) Rotor tip speed m/s
\(a\) Speed of sound at inlet m/s
\(u/a\) Rotor tip Mach number -
\(W_a\) Adiabatic power W
\(W_s\) Shaft power W
\(T_2\) Discharge temperature K

Method and standards

The rotary screw compressor sizing.

Where it is used

  • Selecting oil-free screw compressors.
  • Rerating at a new pressure ratio.

Common mistakes

  • Using the inlet volume as the displacement.
  • Ignoring the built-in volume ratio when rerating.

Assumptions and limits

  • Ideal-gas, uncooled compression; efficiencies from curves.

Questions and answers

Why is the tip speed important?

Leakage back through the clearances is fixed by the clearances, so a slow rotor leaks a larger share; too fast and friction and flow losses grow. Each pressure ratio has an optimum tip Mach number, about 0.25 at a ratio of 3.

What do the defaults represent?

An illustrative case: Hydrocarbon gas M 20, k 1.25, 6 in rotor. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Brown (Bloch and Hoefner), Compressors: Selection and Sizing, 3rd ed. (Gulf Professional Publishing, 2005), ch. 4, eqs. 4.2-4.7 and Examples 4-1 and 4-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.