Worked example
Example: Illustrative 110 kW, 40 C room to 30 C outside. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Present intake temperature (inside the compressor room) | 40.000 °C |
| Cooler intake temperature (outside air) | 30.000 °C |
| Compressor power at present | 110.00 kW |
| Running hours per year | 6,000.0 h |
| Electricity price per kWh (your currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power saved as a share | 3.1934 % |
| Power saved | 3.5127 kW |
| Energy saved in a year | 21.076 MWh |
| Cost saved in a year | 168,609 |
Open this example in the calculator and change any input.
Formula
\(\frac{\Delta P}{P} = 1 - \frac{T_c}{T_h}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_h\) | Present intake temperature (inside the compressor room) | K |
| \(T_c\) | Cooler intake temperature (outside air) | K |
| \(P\) | Compressor power at present | W |
| \(t\) | Running hours per year | s |
| \(c\) | Electricity price per kWh (your currency) | - |
| \(1 - T_c/T_h\) | Power saved as a share | - |
| \(\Delta P\) | Power saved | W |
| \(\Delta E\) | Energy saved in a year | J |
| \(\Delta C\) | Cost saved in a year | - |
Method and standards
Intake temperature.
Where it is used
- Compressed-air energy audits.
- Compressor house ventilation design.
Common mistakes
- Using °C instead of kelvin in the ratio.
- Ducting intake from a sunny roof.
Assumptions and limits
- Same mass flow and pressure ratio; ideal-gas compression.
References
- Compression work proportional to absolute inlet temperature
- Bureau of Energy Efficiency
- Energy Efficiency in Electrical Utilities (Guide Book 3)
- ch. 3 Compressed air system
Questions and answers
How much power does cooler intake air save?
About 1 % for every 3 K: 10 K cooler intake at 40 °C saves 3.2 %.
Is the old rule 1 % per 4 °C right?
It is close: the exact figure is 1 − T_c/T_h with absolute temperatures, slightly more than 1 % per 4 K at normal temperatures.
What do the defaults represent?
An illustrative 110 kW compressor drawing room air at 40 °C instead of outside air at 30 °C, 6,000 h at 8 per kWh.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.