Worked example
Example: Air 14 x 7 in double acting, 100 to 300 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bore | 14.000 in |
| Stroke | 7.0000 in |
| Rod diameter (double acting) | 2.2500 in |
| Speed | 450.00 rpm |
| Action | Double acting |
| Clearance (fraction of displacement) | 15.000 % |
| Inlet pressure | 100.000 psi |
| Discharge pressure | 300.00 psi |
| Inlet temperature | 90.000 °F |
| Isentropic exponent | 1.3950 - |
| Inlet compressibility | 1.0000 - |
| Discharge compressibility | 1.0000 - |
| Loss allowance (0.03-0.05) | 3.0000 % |
| Compression efficiency | 82.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Piston displacement | 553.98 ft³/min |
| Volumetric efficiency | 76.030 % |
| Suction capacity | 421.20 ft³/min |
| Mean piston speed | 525.00 ft/min |
| Discharge temperature (isentropic) | 290.57 °F |
| Cylinder power | 288.84 hp |
Open this example in the calculator and change any input.
Formula
\(P_d = sN(2A - a), \quad E_v = 0.97 - \left[\frac{Z_1}{Z_2}r_p^{1/k} - 1\right]C - L, \quad Q_1 = E_vP_d\)
\(T_2 = T_1r_p^{(k-1)/k}, \quad W = \frac{P_1Q_1\frac{k}{k-1}\left(r_p^{(k-1)/k} - 1\right)}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Bore | m |
| \(s\) | Stroke | m |
| \(d_r\) | Rod diameter (double acting) | m |
| \(N\) | Speed | rad/s |
| \(\text{acting}\) | Action | - |
| \(C\) | Clearance (fraction of displacement) | - |
| \(P_1\) | Inlet pressure | Pa |
| \(P_2\) | Discharge pressure | Pa |
| \(T_1\) | Inlet temperature | K |
| \(k\) | Isentropic exponent | - |
| \(Z_1\) | Inlet compressibility | - |
| \(Z_2\) | Discharge compressibility | - |
| \(L\) | Loss allowance (0.03-0.05) | - |
| \(\eta\) | Compression efficiency | - |
| \(P_d\) | Piston displacement | m³/s |
| \(E_v\) | Volumetric efficiency | - |
| \(Q_1\) | Suction capacity | m³/s |
| \(PS\) | Mean piston speed | m/s |
| \(T_2\) | Discharge temperature (isentropic) | K |
| \(W_{cyl}\) | Cylinder power | W |
Method and standards
The reciprocating cylinder performance method.
Where it is used
- Sizing and rerating process reciprocating compressors.
- Checking vendor capacity claims.
Common mistakes
- Ignoring the rod area in double-acting cylinders.
- Using ideal-gas re-expansion near the critical point.
Assumptions and limits
- Single stage; isentropic temperature; k constant.
Questions and answers
Why does the compressibility ratio matter?
Gas left in the clearance re-expands from discharge to suction; with a real gas the volume it occupies after re-expansion scales with Z₁/Z₂, which can be far from 1 near the critical point.
Why does the rod reduce displacement?
In a double-acting cylinder the crank end has the rod through it, so its swept area is the bore area less the rod area.
What do the defaults represent?
An illustrative case: Air 14 x 7 in double acting, 100 to 300 psia. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Brown (Bloch and Hoefner), Compressors: Selection and Sizing, 3rd ed. (Gulf Professional Publishing, 2005), ch. 3, eqs. 3.2-3.8 and 3.18 and Example 3-1