Worked example
Example: Illustrative 30 m3 at 20 bar + 15 m3 at 60 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Suction-side volume | 30.000 m³ |
| Suction pressure (absolute) | 2.0000 MPa |
| Suction-side gas temperature | 30.000 °C |
| Discharge-side volume (to the check valve) | 15.000 m³ |
| Discharge pressure (absolute) | 6.0000 MPa |
| Discharge-side gas temperature | 60.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Settle-out pressure | 3.3333 MPa |
| Mixed gas temperature (ideal gas, constant c_v) | 47.315 °C |
| Gas in the loop (kmol) | 56.296 |
Open this example in the calculator and change any input.
Formula
\(p_{so} = \frac{p_sV_s + p_dV_d}{V_s + V_d}\;\;(\text{ideal gas, adiabatic mixing})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_s\) | Suction-side volume | m³ |
| \(p_s\) | Suction pressure (absolute) | Pa |
| \(T_s\) | Suction-side gas temperature | K |
| \(V_d\) | Discharge-side volume (to the check valve) | m³ |
| \(p_d\) | Discharge pressure (absolute) | Pa |
| \(T_d\) | Discharge-side gas temperature | K |
| \(p_{so}\) | Settle-out pressure | Pa |
| \(T_{so}\) | Mixed gas temperature (ideal gas, constant c_v) | K |
| \(n\) | Gas in the loop (kmol) | - |
Method and standards
Settle-out balance.
Where it is used
- Compressor station design pressures.
- Relief valve sizing basis.
Common mistakes
- Using the discharge pressure as suction design pressure without checking.
- Ignoring cooler volumes.
Assumptions and limits
- Ideal gas; adiabatic; equal heat capacities.
References
- Ideal-gas settle-out balance
Questions and answers
Why does settle-out pressure matter?
After a trip, high-pressure discharge gas leaks back to the suction side; suction piping, scrubbers and seals must withstand the settled pressure or have relief.
How can it be reduced?
Keep discharge-side volume small by placing check valves close to the compressor, or blow down part of the loop.
What do the defaults represent?
An illustrative loop with 30 m³ at 20 bar and 30 °C on suction and 15 m³ at 60 bar and 60 °C on discharge.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Brown, Compressors: Selection and Sizing, 3rd ed. (Gulf Professional, 2005)