FireCADCalc

Gas Turbine Design-point Cycle: Single Shaft or Free Power Turbine

Specific work, fuel/air ratio, SFC, efficiency and exhaust temperature of a gas turbine with component efficiencies, pressure losses and an optional heat exchanger.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Industrial single shaft, ratio 16, 1,500 K, no heat exchanger

Accepted: 1.5 to 60
Accepted: 426.85 to 1,726.8 °C
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 80 to 100 %
Accepted: 80 to 100 %
Accepted: 0 to 95 %
Accepted: 0 to 20 %
Accepted: 0 to 10 %
Accepted: 0 to 2 bar
Accepted: 0.5 to 1.1 bar
Accepted: -53.15 to 56.85 °C
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 0.9 to 1.4 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 10,000 to 120,000 kJ/kg
Accepted: 0 to 4
Accepted: 0.001 to 1,000 MW

Results

Constant mass flow through the machine, no cooling bleeds, constant c_p and γ for air and for gas as in the textbook method. The fuel/air ratio comes from an enthalpy balance with NIST Shomate data for a CH_y fuel; it reproduces the textbook combustion chart to within about 0.5 %.

Compressor delivery temperature723.78K
Compressor work (per kg air, at the shaft)427.16kJ/kg
Turbine inlet pressure15.560bar
Turbine exhaust temperature (EGT)840.19K
Combustor inlet temperature (after any heat exchanger)723.78K
Specific work output330.31kJ/kg
Fuel/air ratio0.022726
Specific fuel consumption0.24769kg/kWh
Cycle efficiency (LHV)33.722%
Air flow for the power required30.275kg/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Industrial single shaft, ratio 16, 1,500 K, no heat exchanger. The inputs, in the units selected above:

InputValue
ArrangementSingle shaft
Compressor pressure ratio16.000 -
Turbine inlet temperature1,226.8 °C
Compressor isentropic efficiency87.000 %
Turbine isentropic efficiency (each turbine)90.000 %
Mechanical efficiency (each shaft)99.000 %
Combustion efficiency99.500 %
Heat-exchanger effectiveness (0 = none)0 %
Combustor pressure loss4.0000 %
Heat-exchanger air-side loss0 %
Exhaust (and heat-exchanger gas-side) pressure loss0.050000 bar
Ambient pressure1.0130 bar
Ambient temperature29.850 °C
Air specific heat1.0050 kJ/(kg·K)
Air ratio of specific heats1.4000 -
Gas specific heat1.1480 kJ/(kg·K)
Gas ratio of specific heats1.3333 -
Fuel net calorific value43,100 kJ/kg
Fuel H/C atom ratio (kerosene about 1.92, methane 4)1.9200 -
Power required (for the air flow)10.000 MW

Applying the formula below gives:

ResultValue
Compressor delivery temperature723.78 K
Compressor work (per kg air, at the shaft)427.16 kJ/kg
Turbine inlet pressure15.560 bar
Turbine exhaust temperature (EGT)840.19 K
Combustor inlet temperature (after any heat exchanger)723.78 K
Specific work output330.31 kJ/kg
Fuel/air ratio0.022726
Specific fuel consumption0.24769 kg/kWh
Cycle efficiency (LHV)33.722 %
Air flow for the power required30.275 kg/s

Open this example in the calculator and change any input.

Formula

\(T_{02} - T_{01} = \frac{T_{01}}{\eta_c}\left[r_c^{(\gamma_a-1)/\gamma_a} - 1\right], \quad \Delta T_t = \eta_tT_{0i}\left[1 - \left(\frac{1}{r_t}\right)^{(\gamma_g-1)/\gamma_g}\right]\)

\(W = c_{pg}\Delta T_{pt}\eta_m, \quad SFC = \frac{f}{W}, \quad \eta = \frac{W}{fQ_{net}}\)

Variables

Symbol Meaning SI unit
\(\text{arrangement}\) Arrangement -
\(r_c\) Compressor pressure ratio -
\(T_{03}\) Turbine inlet temperature K
\(\eta_c\) Compressor isentropic efficiency -
\(\eta_t\) Turbine isentropic efficiency (each turbine) -
\(\eta_m\) Mechanical efficiency (each shaft) -
\(\eta_b\) Combustion efficiency -
\(\varepsilon\) Heat-exchanger effectiveness (0 = none) -
\(\Delta p_b/p_{02}\) Combustor pressure loss -
\(\Delta p_{ha}/p_{02}\) Heat-exchanger air-side loss -
\(\Delta p_{ex}\) Exhaust (and heat-exchanger gas-side) pressure loss Pa
\(p_a\) Ambient pressure Pa
\(T_a\) Ambient temperature K
\(c_{pa}\) Air specific heat J/(kg·K)
\(\gamma_a\) Air ratio of specific heats -
\(c_{pg}\) Gas specific heat J/(kg·K)
\(\gamma_g\) Gas ratio of specific heats -
\(Q_{net}\) Fuel net calorific value J/kg
\(y\) Fuel H/C atom ratio (kerosene about 1.92, methane 4) -
\(P\) Power required (for the air flow) W
\(T_{02}\) Compressor delivery temperature K
\(W_c\) Compressor work (per kg air, at the shaft) J/kg
\(p_{03}\) Turbine inlet pressure Pa
\(p_{04}\) Power turbine inlet pressure (free turbine) Pa
\(T_{04}\) Gas generator turbine exit temperature K
\(T_{ex}\) Turbine exhaust temperature (EGT) K
\(T_{05}\) Combustor inlet temperature (after any heat exchanger) K
\(W\) Specific work output J/kg
\(f\) Fuel/air ratio -
\(SFC\) Specific fuel consumption kg/J
\(\eta\) Cycle efficiency (LHV) -
\(\dot m\) Air flow for the power required kg/s

Method and standards

Textbook design-point cycle calculation with an enthalpy-balance fuel/air ratio.

Where it is used

  • Preliminary selection of industrial and aero-derivative gas turbines.
  • Cogeneration studies needing exhaust temperature and flow.

Common mistakes

  • Using γ = 1.4 for the hot gas.
  • Forgetting pressure losses, which matter as much as efficiencies.

Assumptions and limits

  • Constant flow; no cooling air; ideal-gas properties with constant c_p.

Questions and answers

How is the power turbine pressure ratio found?

The gas generator turbine must exactly drive the compressor, which fixes its temperature drop and so its pressure ratio; whatever pressure is left above exhaust is expanded in the power turbine.

Why is a heat exchanger not used in combined cycles?

It lowers the exhaust temperature, which the steam cycle needs; it helps only simple-cycle, low-pressure-ratio machines.

What do the defaults represent?

An illustrative case: Industrial single shaft, ratio 16, 1,500 K, no heat exchanger. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 2.3, Examples 2.1 and 2.2; NIST Chemistry WebBook Shomate data for the fuel/air ratio

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.