Worked example
Example: Illustrative ratio 8, intercooled to 300 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor inlet temperature | 15.000 °C |
| Overall pressure ratio | 8.0000 - |
| Turbine inlet temperature | 1,100.0 °C |
| Compressor isentropic efficiency | 85.000 % |
| Turbine isentropic efficiency | 88.000 % |
| Mean specific heat | 1.1000 kJ/(kg·K) |
| Heat capacity ratio | 1.3600 - |
| Air temperature after the intercooler | 26.850 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressor work, single stage | 273.71 kJ/kg |
| Compressor work, intercooled | 241.14 kJ/kg |
| Net specific work, intercooled | 321.52 kJ/kg |
| Efficiency, intercooled | 30.404 % |
| Efficiency, single stage | 31.414 % |
| Compressor delivery, intercooled | 138.67 °C |
Open this example in the calculator and change any input.
Formula
\(w_{c,ic} = c_p\left[T_1\frac{r_p^{k/2} - 1}{\eta_c} + T_{ic}\frac{r_p^{k/2} - 1}{\eta_c}\right], \quad k = \frac{\gamma - 1}{\gamma}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Compressor inlet temperature | K |
| \(r_p\) | Overall pressure ratio | - |
| \(T_3\) | Turbine inlet temperature | K |
| \(\eta_c\) | Compressor isentropic efficiency | - |
| \(\eta_t\) | Turbine isentropic efficiency | - |
| \(c_p\) | Mean specific heat | J/(kg·K) |
| \(\gamma\) | Heat capacity ratio | - |
| \(T_{ic}\) | Air temperature after the intercooler | K |
| \(w_{c,1}\) | Compressor work, single stage | J/kg |
| \(w_{c,ic}\) | Compressor work, intercooled | J/kg |
| \(w_{net}\) | Net specific work, intercooled | J/kg |
| \(\eta\) | Efficiency, intercooled | - |
| \(\eta_0\) | Efficiency, single stage | - |
| \(T_2\) | Compressor delivery, intercooled | K |
Method and standards
Intercooled cycle.
Where it is used
- Peaking and aero-derivative unit studies.
- Compressed air and process compressor trains.
Common mistakes
- Expecting large efficiency gains at low pressure ratio.
- Ignoring intercooler pressure loss.
Assumptions and limits
- Constant c_p and γ; equal stage ratios; no pressure losses.
References
- Air-standard cycle with intercooling
Questions and answers
Why does intercooling not always raise efficiency?
It lowers compressor work but also compressor delivery temperature, so the combustor must add more heat; efficiency gains need high ratios or recuperation.
Why split the pressure ratio equally?
Equal ratios with cooling back to inlet temperature minimise total compressor work.
What do the defaults represent?
An illustrative cycle at pressure ratio 8 with intercooling to 300 K between two equal stages.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers, Cohen and Straznicky, Gas Turbine Theory, 6th ed. (Pearson, 2009)